5 Electrical installation
Item
Heat pump convector
There are different controllers and
setups possible for the heat pump
convectors.
Depending on the setup, you also
need option EKRELAY1.
For more information, see:
▪ Installation manual of the heat
▪ Installation manual of the heat
▪ Addendum
Wires: 0.75 mm²
Maximum running current: 100 mA
For the main zone:
▪ [2.9] Control
▪ [2.A] Thermostat type
For the additional zone:
▪ [3.A] Thermostat type
▪ [3.9] (read-only) Control
Remote outdoor
See:
sensor
▪ Installation manual of the remote
▪ Addendum
Wires: 2×0.75 mm²
[9.B.1]=1 (External sensor =
Outdoor)
[9.B.2] Ext. amb. sensor offset
[9.B.3] Averaging time
Remote indoor sensor
See:
▪ Installation manual of the remote
▪ Addendum
Wires: 2×0.75 mm²
[9.B.1]=2 (External sensor = Room)
[1.7] Room sensor offset
Human Comfort
See:
Interface
▪ Installation and operation manual of
▪ Addendum
Wires: 2×(0.75~1.25 mm²)
Maximum length: 500 m
[2.9] Control
[1.6] Room sensor offset
Installation manual
10
Description
pump convectors
pump convector options
book
for
optional
equipment
outdoor sensor
book
for
optional
equipment
indoor sensor
book
for
optional
equipment
the Human Comfort Interface
book
for
optional
equipment
Item
(in case of DHW tank)
See:
3‑way valve
▪ Installation manual of the 3-way
▪ Addendum
Wires: 3×0.75 mm²
Maximum running current: 100 mA
[9.2] Domestic hot water
(in case of DHW tank)
See:
Domestic hot water
▪ Installation manual of the domestic
tank thermistor
▪ Addendum
Wires: 2
The thermistor and connection wire
(12 m) are delivered with the domestic
hot water tank.
[9.2] Domestic hot water
(in case of DHW tank)
See:
Power supply for
▪ Installation manual of the DHW
booster heater and
thermal protection
▪ Addendum
(from indoor unit)
Wires: (4+GND)×2.5 mm²
[9.4] Booster heater
(in case of DHW tank)
See:
Power supply for
▪ Installation manual of the domestic
booster heater (to
indoor unit)
▪ Addendum
Wires: 2+GND
Maximum running current: 13 A
[9.4] Booster heater
WLAN adapter
See:
▪ Installation manual of the WLAN
▪ Addendum
Use the cable delivered with the
WLAN adapter.
[D] Wireless gateway
LAN adapter
See:
▪ Installation manual of the LAN
▪ Addendum
Wires: 2×(0.75~1.25 mm²). Must be
sheathed.
Maximum length: 200 m
See below ("LAN adapter – System
requirements").
Description
valve
book
for
optional
equipment
hot water tank
book
for
optional
equipment
tank
book
for
optional
equipment
hot water tank
book
for
optional
equipment
adapter
book
for
optional
equipment
adapter
book
for
optional
equipment
ETBH/X16DF6V+9W
Daikin Altherma 3 H HT W
4P586453-1C – 2020.10