Use
at least 17 % volume oxygen in all European countries except
the Netherlands, Begium and the UK
at least 19 % volume oxygen in the Netherlands, Begium and
the UK, Australia and New Zealand
at least 19.5 % volume oxygen in the US
For other countries observe national guidelines.
3.1.1
Special European requirements
Before initial use, the entrepreneur/user must ensure the following
(see European Directive 89/656/EEC):
the fit must be correct to ensure the necessary air-tight fit,
the personal protective equipment must match other types of
protective equipment worn at the same time (e.g. protective
jacket),
the personal protective equipment must be suitable for
respective workplace conditions,
the personal protective equipment must meet ergonomic and
health requirements of the respective wearer of respiratory
protective equipment.
3.2

Preparation for use

3.2.1
Assembling the half mask
1. Arrange the harness.
2. Fit the yoke on the mask body.
3. Fit two new respiratory filters.
3.2.2
Fitting the respiratory filters
1. Hold bayonet-type connector with your hand (refer to figure B).