Herunterladen Diese Seite drucken

Hama Safety Bedienungsanleitung Seite 8

Vorschau ausblenden Andere Handbücher für Safety:

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

00089299bda.indd 9
00089299bda.indd 9
Downloaded from
www.Manualslib.com
Send the device to the following address with a precise description of the fault if it requires service:
Hama GmbH & Co KG
Abt. Service
Industriestraße 10
D- 86653 Monheim
Hama GmbH & Co. KG shall not accept any liability arising from improper use of the inverter or failure to
observe the above safety instructions.
Specifi cations:
Rated input voltage
Input voltage range
Input side connection
Continuous output capacity
Peak output capacity
Output side connection
Output voltage stability
Signal form (output side)
Effi ciency
Idle current consumption
Thermal protection circuit
Short circuit protection
»Soft-start« start switch
Overvoltage protection
Low voltage warning
Low voltage protection
Polarity reversal protection
Residual current deactivation
Fuse
Ambient operating temperature
Dimensions
Weight
Hi-Pot**
*Prevents voltage peaks when switched on
**Isolation test performed in unit test.
manuals search engine
12 V DC
10 V P 15 V DC =
Cigarette lighter plug
150 W
375 W
Shockproof plug (with PE conductor contact)
+/- 10%
Modifi ed sine
> 85%
< 0.3A
60°C +/- 10°C
Yes
Yes
15.0 V +/- 1.0 V DC
10.5 V +/- 0.5 V DC
10.5 V +/- 0.5 V DC
Via fuse
30 mA
1x 20 A fl at vehicle fuse
-15°C to +50°C
192 x 95.6 x 64.5 mm
834 g
Yes
7
15.09.2008 8:55:17 Uhr
15.09.2008 8:55:17 Uhr

Werbung

loading

Diese Anleitung auch für:

00089299