Disposal
10
Disposal
➤ Place the packaging material in the appropriate recycling waste bins
wherever possible.
If you wish to finally dispose of the product, ask your local recycling
M
centre or specialist dealer for details about how to do this in
accordance with the applicable disposal regulations.
11
Technical data
Connection voltage:
Power consumption:
Cooling capacity:
Category:
Energy consumption:
Climate class:
Ambient temperature:
Noise emission:
Refrigerant quantity:
CO
equivalent:
2
Global warming potential
(GWP):
Dimensions (L x W x H):
Weight:
18
MCF32 AC/DC
MCF40 AC/DC
100 – 240 Vw, 50/60 Hz
4 A (12 Vg)
2 A (24 Vg)
1.0 – 0.4 A (100 – 240 Vw)
(+50 °F to +14 °F)
(refrigerator with one or more fresh-food storage
83 kWh/annum
102 kWh/annum
40 g
0.057 t
584 x 365 x
407 mm
11.4 kg
MCF32, MCF40, MCF60 AC/DC
MCF60 AC/DC
12/24 Vg
+10 °C to –10 °C
Category 1
compartments)
N
+16 °C to +32 °C
49 dB(A)
42 g
0.060 t
1430
584 x 365 x
446 mm
11.5 kg
6 A (12 Vg)
3 A (24 Vg)
98 kWh/annum
58 g
0.083 t
680 x 440 x
470 mm
18.4 kg
EN