8.11 Object 200Ah: Laser diode Switch (on/off)

Over object Laser diode Switch the laser diode can be switched off for extension
of the life time and can be switched on again as required. If under the "Object 2005h:
Function ext. Input" the function "LD-switch-input:" (page 68) is selected, this object
does not have a function.
This function immediately gets effective with write access. After operating voltage
OFF/ON the laser diode is switched on again automatically. The save command
"Object 2000h: Accept parameters" cannot be used by this object.
Index
Name
Data type
Access
Value
Default

8.12 Object 200Bh: Failure Quit

If in "Object 2003h: Failure Auto quit" (page 67) the setting is preselected "not
automatic", by setting this bit an occurring error report is deleted. If the error could not
be eliminated, the corresponding bit in the Status-TxPDO is set in the next cycle
again, also see page 64.
Index
Name
Data type
Access
Value
Default

8.13 Object 6000h: Operating Parameters

The object Operating Parameters contains the function for the code sequence.
The code sequence defines whether increasing or decreasing position values are
output with increasing distance to the measuring system.
Index
Name
Data type
Access
Value
Default
Printed in the Federal Republic of Germany
01/21/2016
0x200A
Laserdiode Switch
UNSIGNED8
rw
Bit 0 = 0: Laser diode is/gets switched off
Bit 0 = 1: Laser diode is/gets switched on
1
0x200B
Failure Quit
UNSIGNED8
wo
Bit 0 = 0: Do not delete error report
Bit 0 = 1: Delete error report
0
0x6000
Operating Parameters
UNSIGNED8
rw
Bit 0 = 0: Position values increasing
Bit 0 = 1: Position values decreasing
0