7
INSTALLATION
7.1
General considerations
In the following paragraphs some indications
are provided to be respected in order to obtain
the maximum performance from the purchased
product.
The following indications are how-
ever subject to compliance with any
possible national, regional and mu-
nicipal laws and regulations in force
in the country where the appliance is
installed.
7.2 Installation configurations LINDA
US
The stove can be installed in different ways de-
pending on personal needs:
• Coaxial pipe
• Single wall pipe and air intake in room
• Single wall pipe and outside air intake
80
7.2.1 Coaxial pipe
A coaxial pipe can be used to expel the flue gases
and at the same time withdraw combustion air.
To achieve this:
• Insert the support (A) supplied standard.
• Connect the coaxial pipe (B) (Fig. 32)
It being understood that it is the technician's
responsibility to properly size the chimney
flue based on the installation situation and the
product, it is nonetheless recommended not
to exceed a length of 7 metres with an 8/13 cm
coaxial pipe.
B
A
Fig. 32
004778560 - 06/11/2020