INFORMATION REQUIREMENTS FOR ELECTRIC LOCAL SPACE HEATERS

Model identifier(s):
Item
Heat output HOTI OR1500D
Nominal heat output
Minimum heat output
(indicative)
Maximum continuous
heat output
Auxiliary electricity consumption  
At nominal heat
output
At minimum heat
output
In standby mode
Heat output HOTI OR2000D
Nominal heat output
Minimum heat output
(indicative)
Maximum continuous
heat output
Auxiliary electricity consumption  
At nominal heat
output
At minimum heat
output
In standby mode
Heat output HOTI OR2500D
Nominal heat output
Minimum heat output
(indicative)
Maximum continuous
heat output
Auxiliary electricity consumption  
At nominal heat
output
At minimum heat
output
In standby mode
Información de contacto
HOTI OR
Symbol Value
Unit   Item
Pnom
1,5
kW
Pmin
0,6
kW
Pmax,c
1,5
kW
elmax
N/A
kW
elmin
N/A
kW
elSB
0,00037 kW
Pnom
2,0
kW
Pmin
0,8
kW
Pmax,c
2,0
kW
elmax
N/A
kW
elmin
N/A
kW
elSB
0,00037 kW
Pnom
2,5
kW
Pmin
1
kW
Pmax,c
2,5
kW
elmax
N/A
kW
elmin
N/A
kW
elSB
0,00037 kW
CLIMACITY S.L.
C. Torrox, 2 - 5 · 28041 Madrid (ESPAÑA)
tel. +34 91 392 05 09
EN
Type of heat input, for electric storage local
space heaters only (select one)
  manual heat charge control, with integrated
thermostat
  manual heat charge control with room and/or
outdoor temperature feedback
  electronic heat charge control with room and/
or outdoor temperature feedback
  fan assisted heat output
  Type of heat output/room temperature control
(select one)
  single stage heat output and no room
temperature control
  Two or more manual stages, no room
temperature control
with mechanic thermostat room temperature
control
with electronic room temperature control
electronic room temperature control plus day
timer
electronic room temperature control plus
week timer
Other control options (multiple selections
possible)
room temperature control, with presence
detection
room temperature control, with open window
detection
with distance control option
with adaptive start control
with working time limitation
with black bulb sensor
14
Unit
N/A
[no]
[no]
[no]
[no]
[no]
[no]
[no]
[yes]
[no]
[no]
N/A
[no]
[no]
[no]
[no]
[yes]
[no]