Herunterladen Inhalt Inhalt Diese Seite drucken

Braun 5 Serie Gebrauchsanweisung Seite 14

Vorschau ausblenden Andere Handbücher für 5 Serie:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
Trouble-Shooting
Problem
SHAVER
Unpleasant smell
from the shaver head.
Battery performance
dropped significantly.
Shaving performance
dropped significantly.
Battery segments
in the display
are skipped with
decreasing battery
capacity.
Shaver head is
humid.
CLEAN&CHARGE STATION
Cleaning does not
start when pressing
the start button.
Increased
consumption of
cleaning fluid.
Guarantee
We grant a 2 year guarantee on the product commencing on the date of purchase. Within the guarantee
period we will eliminate any defects in the appliance resulting from faults in materials or workmanship,
free of charge either by repairing or replacing the complete appliance at our discretion.
This guarantee extends to every country where this appliance is supplied by Braun or its appointed
distributor.
This guarantee does not cover: damage due to improper use, normal wear or use as well as defects that
have a negligible effect on the value or operation of the appliance. The guarantee becomes void if repairs
are undertaken by unauthorised persons and if original Braun parts are not used.
To obtain service within the guarantee period, hand in or send the complete appliance with your sales
receipt to an authorised Braun Customer Service Centre (address information available online at
www.service.braun.com)
14
Possible reason
1. Shaver head is cleaned with
water.
2. Cleaning cartridge is in use
for more than 8 weeks.
1. Foil and cutter are worn
which requires more power
for each shave.
2. Shaver head is regularly
cleaned with water but not
lubricated.
1. Foil and cutter are worn.
2. Shaving system is clogged.
Foil and cutter are worn which
requires more power for each
shave.
1. Drying time after automatic
cleaning was too short.
2. Drain of the Clean&Charge
Station is clogged.
1. Shaver is not placed properly
in the Clean&Charge Station.
2. Cleaning cartridge contains
not enough cleaning fluid
(display blinks red).
Drain of the Clean& Renew
station is clogged.
Remedy
1. When cleaning the shaver head with water only
use hot water and from time to time some liquid
soap (without abrasive substances). Remove
Foil & Cutter cassette to let it dry.
2. Change cleaning cartridge at least every 8 weeks.
1. Renew Foil & Cutter cassette.
2. If the shaver is regularly cleaned with water, apply
a drop of light machine oil on top of the foil once
a week for lubrication.
1. Renew Foil & Cutter cassette.
2. Soak the Foil & Cutter cassette into hot water
with a drop of dish liquid. Afterwards rinse it
properly and tap it out. Once dry apply a drop of
light machine oil on the foil.
– Renew Foil & Cutter cassette.
– Regularly oil the shaving system, especially when
cleaning with water only.
1. Clean directly after shaving to allow enough time
for drying.
2. Clean the drain with a wooden toothpick.
1. Insert shaver into the Clean&Charge Station and
push it to the rear side of the station (contacts
of the shaver need to align with contacts in the
station).
2. Insert new cleaning cartridge. Press start button
again.
– Clean the drain with a wooden toothpick.
– Regularly wipe the tub clean.

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis