ELECTRICAL INSTALLATION
• The electrical system must be compliant with the rule IEC 64-8.
• The product must be connected to the mains using a single-pole
switch with a contact opening that ensures complete disconnec-
tion in category III overvoltage conditions (3mm minimum) located
outside of zones 0, 1, 2 (IEC 64-8/7).
• Make sure the product gets power through a differential switch
with an intervention threshold ≤30mA.
N.B. The power cord from the mains must only be replaced by
specialist technicians.
• The electrical connection (
Earthing system that must be:
- Of a fixed type.
- Adequate for the current absorbed (refer to the data on the
data reference plate).
- With an IPX5 resistance rating against the penetration of
liquids.
• The supplied cable (if present) must be used for the mains con-
nection.
• If the product does not come with the power cable, or if it must be
replaced, the type used must be at least H05VV-F/60277 IEC 53,
with a diameter suited to the cable glands on the appliance.
EQuIPOTENTIAL CONNECTION
Furthermore, the product must be connected to the main equipo-
tential point using an appropriate Earth clamp attached to a boiler
support bracket.
SHOWER CABIN CuBIC vOLuME AND POWER
OuTPuT OF THE STEAM GENERATOR
It is recommended to install adequate insulation on the walls of the
shower cabin to quickly reach the optimum sauna temperature.
The data and characteristics indicated do not commit Teuco SpA, who reserves the right to make any modifications thought necessary without notice or substitution.
14
~
) must include the connection to an
WATER INSTALLATION
• Predispose the hot and cold water connections to feed the tap fit-
tings and the connection of the discharge outlet. If the hardness of
the water is high (>200 mg/litre) install a water softener to ensure
a good functioning of the system.
• To ensure the correct functioning of the water functions,
the water supply system must have the following charac-
teristics:
- Min./max. pressure of the water supply: 2.5 - 5 bar
(250 - 500 kPa);
- recommended mains pressure 3.5 bar (350 kPa);
- Max. hot water temperature 60°C;
-
min/max flow rate 20 ÷ 35 l/min;
- min/max thermal input 55 ÷ 82Kw;
- min. discharge u-bend flow rate 35 l/min.
• By way of example, two types of installation are shown; they
are not binding for the customer, who will adopt the most suitable
solution for his own requirements, according to required heat rat-
ing.
Instant production of hot water: the use of one or more
-
boilers properly sized to obtain an average heat rating of
68Kw, with 3.5 bar mains pressure and 60° domestic hot
water, permits to have a theoretically unlimited shower time,
when other simultaneous utilities are not present;
-
Storage system production: the use of a storage system
corresponding to approx.ly 250 litres, with mains pressure
3.5 bar and 60° water temperature in the boiler, permits to
obtain approx.ly uninterrupted 15 minutes of water mixed at
38° (cold water temperature ≥10°C), if no other simultaneous
utilities, taking hot water from the same system, are present.
Please note: the higher the storage system capacity, the
larger the hot water amount available, therefore the available
shower time.
NOTE. The equipped column functions may be used in
an independent manner; when used at the same time,
the performance depends on the mains system fea-
tures. The product is tested to ensure the optimal per-
formance of the water functions used singularly.