3.9 Automatic equalization
Automatic equalization is default set to 'OFF'. With the Victron Connect app
(see sect 1.12) this setting can be configured with a number between 1
(every day) and 250 (once every 250 days).
When automatic equalization is active, the absorption charge will be followed
by a voltage limited constant current period. The current is limited to 8% or
25% of the bulk current (see table in sect. 3.5). The bulk current is the rated
charger current unless a lower maximum current setting has been chosen.
When using a setting with 8% current limit, automatic equalization ends
when the voltage limit has been reached, or after 1 hour, whichever comes
first.
Other settings: automatic equalization ends after 4 hours.
When automatic equalization is not completely finished within one day, it will
not resume the next day, the next equalization session will take place as
determined by the day interval.