A binary LED code helps determining the position of the rotary switch.
After changing the position of the rotary switch, the LEDs will blink during 4
seconds as follows:
Switch
position
0
1
2
3
4
5
6
7
Thereafter, normal indication resumes, as described in the LEDs section.
3.10 LEDs
LED indication:
⚫
permanent on
blinking
off
Regular operation
Not charging (*1)
Bulk
Absorption
Manual equalisation (blink
alternating)
Automatic equalisation
Float
Note (*1): The bulk LED will blink briefly every 3 seconds when the system is powered but
there is insufficient power to start charging.
Fault situations
Charger temperature too high
Charger over-current
Charger or panel over-voltage
VE.Smart networking or BMS
issue
Internal error (*2)
Note (*2): E.g. calibration and/or settings data lost, current sensor issue.
11
LED
LED
Bulk
Abs
1
1
0
0
0
1
0
1
1
0
1
0
1
1
1
1
LEDs
LEDs
LED
Float
frequency
1
1
0
1
0
1
0
1
Bulk
Absorption
⚫
⚫
⚫
Bulk
Absorption
Blink
Fast
Slow
Slow
Slow
Slow
Slow
Slow
Slow
Float
⚫
⚫
Float