7. Connections with a Controller
7-1. Wiring Connections with a Controller
Th is product and the controller that supports the SIEMENS DRIVE-CLiQ can be connected with a cable made by
SIEMENS. Both of the power and signal can be connected with a cable made by SIEMENS.
Extension connection cables
PHOENIX CONTACT Inc.
SACC-M12FS-8Q SH
8
2
TX-P
7
TX-N
6
RX-P
3
RX-N
4
24 V
1
0 V
5
Connection Example 1
Rotary magnescale
Connection Example 2
Rotary magnescale
Extension connection cable ①
SIEMENS model no. 6FX8002-2DC34-
Extension connection cable ②
SIEMENS model no. 6FX8002-2DC30-
AS for the specifi cations of extension connection cables and purchasing of the cables, contact SIEMENS.
10
(E)
PHOENIX CONTACT Inc.
SACC-M12MS-8Q SH
TX-P
TX-N
RX-P
RX-N
24 V
0V
Shield
Extension
connection cables
Head Cable
30
Head Cable
30
Extension connection cables
PHOENIX CONTACT Inc.
SACC-M12FS-8Q SH
8
2
TX-P
7
TX-N
6
RX-P
3
RX-N
4
24 V
1
0V
5
Extension
connection cables
Extension
connection cables
To the controller that supports
the SIEMENS DRIVE-CLiQ
Yamaichi Electronics Co., Ltd.
CN078P-061-0001
RX-P
RX-N
TX-P
TX-N
24 V
0 V
Shield
The controller
that supports
the SIEMENS DRIVE-CLiQ
The controller
that supports
the SIEMENS DRIVE-CLiQ
RS97-1024EGZ Series
3
6
1
2
A
B