CONDOR - connection diagram of the motors [1/2]
• DELAY LED OFF = DELAY OF THE MOTOR n.2
1

• DELAY LED ON = DELAY OF THE MOTOR n.1

1
Configuration - MASTER ON THE LEFT, SLAVE ON THE RIGHT
MOTOR n.1 WITH CONTROL UNIT (on the left)
BLACK with OP1

COMMON with CM1

BROWN with CL1
Blue
Black
Brown
F2
CN2
ELS
ELS
LAMP
FOT+
GND
DS2
DS1
GND
PED
PP
SEL
SET
ANT-
ANT+
MOTOR n.2 WITHOUT CONTROL UNIT (on the right)
OPEN with CL2

COMMON with CM2

CLOSED with OP2