6. SLAM LOCK:
The control unit is factory set with the Slam Lock function disabled. This
function consists in adding, in the presence of a deceleration stage during
closing, 1 extra second at the maximum power or at the power selected
with the "FORCE" trimmer, in such a way as to ensure positive engagement
of the gate lock, if installed. If you want to enable the Slam Lock function
at maximum power, proceed as follows: make sure you have enabled
Extended Menu 1, use the SELECT key to select blinking LED L6 and then
press the SET key: LED L6 becomes steady on and programming will be
completed. If you want to enable the Slam Lock function at the power set
with the "FORCE" Trimmer, repeat the operation described by pressing the
SELECT key twice (LED L6 will blink rapidly) rather than once. Repeat the
procedure if you want to restore the initial configuration.
7. PREFLASHING/COURTESY LIGHT:
The control unit is factory set with the Preflashing and Courtesy Light
functions disabled. If you want to enable the Preflashing function proceed
as follows: make sure you have enabled Extended Menu 1, use the SEL key
to select blinking LED L7 and then press the SET key: the LED becomes
steady on and programming will be completed. If you want to enable the
Courtesy Light function, repeat the operation described above, pressing
the SELECT key twice (the LED will blink rapidly) rather than once. Repeat
the procedure if you want to restore the initial configuration.
Preflashing Operation: the 24 Vac 4W max. Flashing Light output will
always switch on 3 seconds before the gate starts the closing operation.
Courtesy Light Operation: the 24 Vac 4W max. Courtesy Light output
will switch on for 3 minutes whenever an opening command is transmitted.
EXTENDED MENU 2
The control unit is factory set to allow direct selection exclusively of the main
menu functions. If you want to enable the functions described in Extended
Menu 2, proceed as follows: select blinking LED LEV and press SET twice.
The LED will start blinking alternately 1 1 0 1 1 0 1 1 0. This means there is
a period of 30 seconds to select the functions in Extended Menu 2 using
the SELECT and SET keys and then, after a further 30 seconds, the control
unit will revert to the main menu.
L1
SOFT STOP
L2
SOFT START
L3
DS1 IN OPEN
L4
HOLD-TO-RUN
L5
FOLLOW ME
L6
PAUSE FLASHING
L7
ALWAYS CLOSE
LEV
MENU
1. SOFT STOP:
The control unit is factory set with the Soft Stop function disabled. If you
wish to enable the function, proceed as follows: ensure you have enabled
Extended Menu 2 and then use the SEL key to select blinking LED L1
and press the SET key; at the same time LED L1 becomes steady on and
programming will be completed. With this function enabled at the end of
the movement the control unit will reduce operator force to zero gradually
in a 2 second interval. Repeat the procedure if you want to restore the
previous configuration.
2. SOFT START:
The control unit is factory set with the Soft Start function disabled. If you
wish to enable the function, proceed as follows: ensure you have enabled
Extended Menu 2 and then use the SEL key to select blinking LED L2
and press the SET key; at the same time LED L2 becomes steady on
and programming will be completed. With this function enabled at the start
of each movement the control unit will modulate start-up of the operator,
gradually increasing the force from the minimum to the value set by the
"FORCE" trimmer during the first 2 seconds of operation. Repeat the
procedure if you wish to restore the previous configuration.
Note: when the Soft Start function is enabled, the control unit automatically
disables the Starting Torque function, while if Soft Start is disabled, then
Starting Torque is automatically enabled.
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
2 FLASHIES
3. DS1 ALSO IN OPENING:
The control unit allows the operation of input DS1 to be modified. If you
want DS1 to operate also during opening (momentary stopping of the gate,
as soon as it is freed the control unit resumes the opening movement),
proceed as follows: ensure you have enabled Extended Menu 2 and then
press the SEL key to select blinking LED L3 and press the SET key: LED L3
becomes steady on and programming will be completed.
Repeat the procedure if you want to restore the initial configuration.
4. HOLD-TO-RUN:
The control unit provides the opportunity to set the "Hold-to-Run" function.
If you wish to enable the function, proceed as follows: ensure you have
enabled Extended Menu 2 and then use the SEL key to select blinking LED
L4 and press the SET key; at the same time LED L4 becomes steady on
and the operation will be completed.
With this function enabled using either the remotes or the Pushbuttons to
operate the gate, the following operation will be obtained: the command
must be maintained constantly to move the gate. When the command is
released movement will stop immediately. Repeat the procedure if you want
to restore the previous configuration.
5. FOLLOW ME
The control unit allows the "Follow me" function to be configured;
programmable only if a Pause Time has already been set, this function
reduces the Pause Time to 5 seconds after freeing the SAFE1 photocells,
meaning the gate re-closes 5 seconds after transit of the user. To activate
this function proceed as follows: ensure you have enabled Extended
Menu 2 and then press the SELECT key to select blinking LED L5 and
then press the SET key: LED L5 becomes steady on and programming
will be completed. Repeat the procedure if you want to restore the
previous configuration.
6. FLASHING LIGHT OPERATION
The control unit is factory set with Flashing Light operation during Pause
Time disabled. If you want to enable this function, proceed as follows: make
sure you have enabled Extended Menu 2, press the SELECT key to select
blinking LED L6 and then press the SET key: LED L6 becomes steady
on programming will be completed. Repeat the procedure if you want to
restore the previous configuration.
7. ALWAYS CLOSE FUNCTION
The control unit provides the facility to set "Always Close" operation: this
function, which is programmable only if a Pause Time has already been
programmed, is activated after a power loss; if the gate open condition
is confirmed a closing movement is started automatically, preceded by
5 seconds of preflashing. If you wish to enable the function, proceed as
follows: ensure you have enabled Extended Menu 2 and then use the SEL
key to select blinking LED L7 and press the SET key; at the same time LED
L7 becomes steady on and the operation will be completed. Repeat the
procedure if you want to restore the previous configuration.
RESET
If it becomes necessary to reset the control unit to restore the factory
settings, press the SELECT and SET keys together; this will cause all the
RED indicator LEDs to light simultaneously followed immediately by the
control unit switching off.
DIAGNOSTICS
Photocell Test:
The control unit is prearranged for connection of safety devices in
compliance with standard EN 12453 point 5.1.1.6. At each operating
cycle a functional test of the connected photocell is performed. In the case
of an open circuit and/or malfunctioning of the photocell, the control unit
does not enable movement of the gate and visually signals the test failed
condition by causing all the indicator LEDs to blink simultaneously. As soon
as correct operation of the photocell is restored,the control unit is ready for
normal use. This operating mode guarantees failure mode monitoring in
compliance with EN 954-1 Category 2.
Commands input test:
In correspondence with each low voltage command input the control unit
is equipped with an indicator LED so that the status of the input can be
checked at a glance.
Operating logic: LED on input closed, LED off input open.
COMUNELLO ®Copyright 2014 - All right reserved
21