Herunterladen Inhalt Inhalt Diese Seite drucken

Technical Data; Technical Data - Electrical Ratings; Technical Data - Electrical Ratings (Encoder); Technical Data - Electrical Ratings (Centrifugal Switch) - Baumer POG 90 + FSL Montage- Und Betriebsanleitung

Inkrementaler grehgeber mit integriertem fleihkraftschalter
Inhaltsverzeichnis

Werbung

8

Technical data

8
Technical data
8.1

Technical data - electrical ratings

• Interference immunity:
• Emitted interference:
• Approval:
8.2

Technical data - electrical ratings (encoder)

• Voltage supply:
• Consumption w/o load:
• Pulses per revolution:
• Phase shift:
• Duty cycle:
• Reference signal:
• Output frequency:
• Output signals:
• Output stages:
• Sensing method:
8.3

Technical data - electrical ratings (centrifugal switch)

• Switching accuracy:
• Switching deviation cw-ccw rotation: ≤3 %
• Switching hysteresis:
• Switching outputs:
• Output switching capacity:
• Minimum switching current:
25
EN 61000-6-2
EN 61000-6-3
CE
9...30 VDC (HTL, TTL - version R)
5 VDC ±5 % (TTL)
≤100 mA
1024...10000 (as ordered)
90° ±8°
44...56 %
Zero pulse, width 90°
≤250 kHz
K1, K2, K0 + inverted
HTL
TTL/RS422
(as ordered)
Optical
±4 % (Δn = 2 rpm/s)
≤ +20 % (Δn = 1500 rpm/s)
≈40 % of switching speed
1 output, speed control
≤6 A / 230 VAC
≤1 A / 125 VDC
50 mA
Baumer_POG90-FSL_II_DE-EN (19A3)
MB154.1 - 11064671

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis