Technical Data
11.1.7
Background
NOTE
6SE7035-1TJ 0-1AA0
6SE7036-0TJ 0-1AA0
6SE7037-0TJ 0-1AA0
6SE7037-0TK 0-1AA0
6SE7038-6TK 0-1AA0
6SE7041-1TK 0-1AA0
6SE7041-3TL 0-1AA0
11-22
Downloaded from
www.Manualslib.com

Characteristic data of water-cooled units, types J, K and L

The tables listed below give the rated water flow volume in l/min and
the pressure difference (in Pa) across the heat sink at rated flow
volume.
The water-cooled units have a lower power loss (i.e. a higher efficiency)
than the air-cooled units. The power loss is given in table 11-8.
MASTERDRIVES with water-cooling have the same power rating as
the air-cooled units. Since the thermal resistance of the heat sinks for
the IGBT is distinctly better than that attainable with air-cooling, the
modules are operated with a junction temperature that is 20 K lower.
The result of this is that the module losses are about 5 % lower.
This effect also gives the modules a good life expectancy.
Many units are also equipped with small built-in fans. The lower power
losses of these can also be taken into account.
In the tables below, the data for new units or more exact data are
printed in bold type.
MLFB
Flow
Differential
[l/min]
24
26
30
30
40
46
51
= 5 corresponds to MASTERDRIVES Motion Control
= 7 corresponds to MASTERDRIVES Motion Control Performance 2
Table 11-8
*
The sound level was determined under the following boundary conditions:
Distance to the unit 1 m, height above floor level 1 m, distance to the next reflecting
wall 4 m, room height 6m.
The chassis were installed in Siemens 8MC cabinets without any special
soundproofing measures.
manuals search engine
Sound
Sound
pressure
level
level
IP20
IP42
[Pa]
[dBA]*
[dBA]*
76
75
16900
76
75
19840
27270
76
75
76
76
9300
76
76
16560
76
76
21900
75
74
12000
Characteristic data of DC units, 510 V to 650 V
Operating Instructions
06.2006
Sound
Water
Power
level
heating
loss
IP54
[dBA]*
[k]
[kW]
72
4
5.58
72
4
6.39
72
4.5
7.74
73
5
9.05
73
5
10.4
73
5
10.7
71
5
12.3