06.2006
Re-installing the unit
NOTE
Siemens AG
SIMOVERT MASTERDRIVES
Downloaded from
www.Manualslib.com
Re-install the CU board or the adaption board in the electronics box as
follows:
♦ Insert the CU board into mounting position 1 and the adaption board
into mounting position 2 or 3.
The mounting position 3 can only be used when an adaption board or a
technology board has been mounted in mounting position 2.
Boards should first be installed in mounting position 2, before mounting
position 3 is used.
♦ Secure the CU board/adaption board at the handles with the fixing
screws.
Re-connect the previously removed connections.
Check that all the connecting cables and the shield sit properly and are
in the correct position.
6SE7087-6KN50
Operating Instructions
manuals search engine
Installation
5-11