3. Specification
The following Specification assume a one year calibration cycle and an operating temperature of 64°F
to 82°F (18℃ to 28℃)at a relative humidity of up to 80% unless otherwise noted.
3.1 AC Current (Average sensing, calibrated to rms of sine ware)
Range
2000 mA
20 A
600 A
Input impedance:
9 MΩ
Overload protection: 600A on all ranges.
Max. claw opening: 50 mm (2")
3.2 AC Voltage(Average sensing, calibrated to rms of sine wave)
Range
200 V
600 V
Input impedance: 9MΩ
Overload protection: 600V AC/DC on all ranges.
3.3 DC Voltage
Range
200 V
600 V
Input impedance:9MΩ
Overload protection: 600V DC/peak AC on all ranges.
3.4 Continuity Test
Buzzer sound when resistance is lower than 75Ω
Overload protection: 300V DC/peak AC
3.5 Resistance
Range
200 Ω
200 KΩ
Overload protection: 250V DC/rms AC
3.6 Environment
Temperature
Relative Humidity
SW-Stahl und Werkzeugvertriebs GmbH
L
e
v
e
k r
u
s
r e
t S
a r
s
s
e
6
5
D
4 -
2
8
9
7
R
e
m
s
c
h
e
d i
Resolution
1 mA
10 mA
1 A
Resolution
100 mV
1 V
Resolution
100 mV
1 V
Resolution
0,1 Ω
100 Ω
Normal operation
Usable condition
Storage
max. 80% RH
Tel. +49 (0) 2191 / 46438-0
F
ax +49 (0) 2191 / 46438-40
- E
M
a
: l i
n i
o f
@
s
w
Accuracy (50Hz – 60Hz)
±(2,5% +10 Digit)
±(2% +5 Digit)
Accuracy (50Hz – 500Hz)
±(1,0% +5 Digit)
±(1,2% +5 Digit)
Accuracy
±(0,2% +2 Digit)
±(1,0% +2 Digit)
Accuracy
±(1,0% +10 Digit)
±(1,0% +4 Digit)
18°C bis 28°C (64°F bis 82°F)
0°C bis 50°C (32°F bis 122°F)
-20°C bis 60°C (- 30°F bis 140°F)
s
a t
l h
d .
e