Herunterladen Inhalt Inhalt Diese Seite drucken

Cleaning Station Sub-Assembly En; Putting Into Operation - Abicor Binzel BRS-LCi Betriebsanleitung

Vorschau ausblenden Andere Handbücher für BRS-LCi:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

6 Putting into operation

5.1 Cleaning station sub-assembly
S4 Inductive proximity switch (stroke on top)
1
S2 Inductive proximity switch (clamp - open)
2
Y2 5/2-way valve for clamping device (clamp - unscrew) and
3
motor (on - off)
Y1 5/2-way valve for milling cutter stroke (bottom - top)
4
Cleaning station sub-assembly
Fig. 3
6 Putting into operation
Risk of injury due to unexpected start-up.
For the entire duration of maintenance, servicing, dismounting and repair work, the following instructions
must be adhered to:
• Switch off the power supply.
• Cut off the compressed air supply.
• Cut off the gas supply.
• Pull the mains plug.
NOTE
• The cleaning station may only be put into operation by trained personnel.
• Make sure that the cleaning process is not impaired by the collecting tray and the bottle holder.
EN - 8
1
2
3
8
7
5
6
7
8
DANGER
4
5
6
Y3 5/2-way valve for injection unit
S3 Inductive proximity switch (motor rotates)
Harting plug
S1 Inductive proximity switch (stroke on top)
BRS-LCi

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis