PLUMBING DIAGRAMS
LEGEND
GRADUATED THERMOMETER UP TO 120°
Gauge holder cock
RADIAL GAUGE, 0-4 BAR SCALE
Manually resettable shutdown pressure switch
I.S.P.E.S.L. APPROVED ADJUSTMENT THERMOSTAT
I.S.P.E.S.L. APPROVED MANUALLY RESETTABLE SHUTDOWN
THERMOSTAT
I.S.P.E.S.L. approved thermostat
On-off valve
Ball valve
Calibration valve
Heat exhaust valve
Check valve
Circulator
I.S.P.E.S.L approved safety valve calibrated at 2.7 bar
Thermostatic mixer
Automatic air breather device with cock
Closed expansion tank
Open expansion tank
acoustic alarm device;
Breather pipe
OPEN EXPANSION TANK SIZING
TANK CAPACITY
SYSTEM CAPACITY
30 litres
OPEN TANK SYSTEMS (CHAPTER R.3.A. OF THE M.D. 01.12.1979)
THE EXPANSION TANK MUST COMPRISE A COVERED CONTAINER,
SITUATED ABOVE THE HIGHEST POINT REACHED BY THE WATER
CIRCULATING INSIDE THE SYSTEM, FITTED WITH A BREATHER PIPE
THAT COMMUNICATES WITH THE ATMOSPHERE, ITS SECTION MUST
BE NO LESS THAN THAT OF THE SAFETY PIPE AND IT MUST BE
IMPOSSIBLE TO CLOSE. THE SAFETY PIPES AND THE OVERFLOW
PIPES MUST BE PROTECTED AGAINST FREEZING. THE HEAT
GENERATORS, WITH A CAPACITY HIGHER THAN 35 KW AND FED WITH
NON-ATOMISED SOLID FUEL, CAN ONLY BE INSTALLED IN OPEN
EXPANSION TANK TYPE SYSTEMS.
MAXIMUM SIZE OF THE SAFETY PIPE (CHAPTER R.2.A. OF THE M.D.
01.12.1975)
INSIDE DIAMETER OF THE SAFETY PIPE
MAXIMUM LENGTH OF THE SAFETY PIPE
I=20 mm (3/4")
40 m
NB: THE INSIDE DIAMETER OF THE SAFETY PIPE MUST BE AT LEAST 20
mm, IT MUST HAVE NO REVERSE GRADIENTS EXCEPT FOR THE
SECTION THAT COMES THROUGH INTO THE TOP OF THE EXPANSION
TANK, ITS RADIUS OF CURVATURE MUST BE NO LESS THAN 1.5 TIMES
THE INSIDE DIAMETER OF THE PIPE AND IT MUST HAVE NO TOTAL OR
PARTIAL CUT-OFF DEVICES
PLUMBING DIAGRAMS
OPEN TANK SYSTEM
HEATING FIREPLACE WITH/WITHOUT
PRODUCTION OF SANITARY HOT WATER (BI300)
CONNECTION WITH BOILER
CONNECTION WITHOUT BOILER
STORAGE TANK BOILER
MANIFOLD
Insulator made to standard, L. 10/91
SEE DETAIL No. 1
HEATING FIREPLACE WITH/WITHOUT PRODUCTION OF
SANITARY HOT WATER (BI300) IN PARALLEL WITH A
Downloaded from
www.Manualslib.com
manuals search engine
TRADITIONAL BOILER
OPEN TANK AND CLOSED TANK SYSTEM
HEATING FIREPLACE WITH/WITHOUT PRODUCTION OF
SANITARY HOT WATER (BI300) IN PARALLEL WITH A
GAS BOILER
TECHNICAL FEATURES
From Palazzetti's constant technological research work, a new heat
generator has been created, an updated version of the proven
Termopalex Monoblocco. A true heating machine, model BI 300 with the
production of sanitary water and model BS 300 without boiler, that is
able to heat the radiators all through the home and, thanks to the storage
tank boiler (a standard feature only on the BI 300 model), supply hot
sanitary water for all the family. It can work as the only heating source
or it can be combined with an existing system.
Fireplace model:
Monoblocco
Termopalex
Kcal/h
kW
Total Thermal power (yield) *
Direct thermal power (to fluid)
Water content (L)
Max. running pressure
(bar)
2
Exchange surface (m
)
Smoke outlet (cm)
External air intake.
Weight (Kg.)
Solid fuel
Construction material
Firewood
box steel 3 mm
Production of sanitary water (BI 300) with vitrified boiler with internal
coil
Water content (L)
Height
Flue section
650 cm and over
450 ÷ 650 cm
350 ÷ 450 cm
* Power obtained with an average consumption of 8 Kg/h of firewood
M = heating system delivery pipe
R = heating system return pipe
S = discharge
I = sanitary system inlet
U = hot sanitary water outlet
19