6 Select the image for the next boot by entering the boot system command. After this
command, enter the show bootvar command to verify that the copy indicated as a
parameter in the boot system command is selected for the next boot.
The following is an example of the information that appears:
console# boot system image-2
console# show boot
Images currently available on the Flash
Image-1 active
Image-2 not active (selected for next boot)
If the image for the next boot is not selected by entering the boot system command,
the system boots from the currently active image.
7 Enter the reload command. The following message is displayed:
console# reload
This command will reset the whole system and disconnect
your current session. Do you want to continue (y/n) [n]?
8 Enter y.
The Ethernet switch module reboots.
Gb Pass-through Module
Gb Pass-through Module Link Negotiations
A Gb pass-through module external port negotiates a link with an external device whether a server
module is installed or not. This is because the Gb pass-though module uses the SerDes interface
for internal connectivity to the server modules.
NOTE:
The Gb Ethernet module must be connected to a 1000 Mb port on the external switch (10 Mb and
100 Mb ports are not supported).
The following cases describe normal behavior of the Gb pass-though module when a cable is
connected from an external port on the module to an external switch.
•
A link is displayed at both the external switch and at the Gb pass-through module if a server
module is installed or a Gb Ethernet daughter card is installed in the server module.
•
A link is displayed only at the external switch if a server module is not installed or a Gb
Ethernet daughter card is not installed in the server module. A link is not displayed at the Gb
pass-through module.