7
COMMISSIONING
7.2
Sensing range
7.3
Settings
10
Observe the application conditions: Adjust the distance between the sender and the
receiver according to the corresponding diagram [see
operating reserve).
When mounting through beam photoelectric sensors adjacent to each other, alternate
the sender (GS6L) and receiver (GE6L) arrangement every other pair. Also ensure that
there is sufficient distance between pairs based on the sender (GS6L) light spot diame‐
ter. By doing this, mutual interference can be prevented [see
Use
table 3
to check the function. If the switching output fails to behave in accordance
with
table
3, check the application conditions.
Operating reserve
100
10
1
0
10
20
(32.80)
(65.62)
Figure 3: Characteristic curve, GSE6L
Sensitivity setting
Sensor which it is not possible to set: The sensor is adjusted and ready for operation.
The sensitivity is adjusted with the potentiometer (type: 5-turn). Clockwise rotation:
operating reserve increased; counterclockwise rotation: operating reserve reduced. We
recommend setting the potentiometer to "Maximum".
The sensor is adjusted and ready for operation.
figure
30
40
(98.43)
(131.23)
Distance in m (feet)
3] (x = sensing range, y =
figure
1].
8025390 | SICK