- If the room temperature drops 2 degrees below
the set temperature, the heater will start run-
ning at intensity I (1000W).
- If the room temperature drops 4 degrees below
the set temperature, the heater will start run-
ning at intensity II (2000W).
WEEKLY PROGRAM SET UP:
- The appliance can be programmed to function
at specific times and days throughout the week.
- To initiate this function press the "W.Timer"
button (V).
- Use the "+" (XI) or "-" (VI) buttons to select the
the desired program (P1-P6). Check table 1
to see the settings for each program. The W
indicator (10) will turn on.
- P6 is the customizable program.
- Once you reach P6, press the "W.Timer" button
(V) again to program Mondays. The "Mo" indi-
cator (3) will turn on.
- Press the "W.Timer" button (V) again to set the
starting time. The "ON" indicator (5) will turn
on.
- Use the "+" (XI) or "-" (VI) buttons to select
the desired starting hour (1-24h). Press the
"W.Timer" button (V) again and use the "+" (XI)
or "-" (VI) buttons to select the desired starting
minutes (0-59min).
- Press the "W.Timer" button (V) again. The
"OFF" indicator (6) will turn on.
- Follow the same process as before to set the
ending hours and minutes.
- Press the "W.Timer" button (V) once more to
set up the rest of the days, following the same
process.
- Once you have selected the program or
customized P6, press the "Delay" button (IX)
to set the desired temperature for each day of
the week.
- Use the "+" (XI) or "-" (VI) buttons to select the
desired temperature (10-49ºC).
- Repeat the process for each day of the week.
OPEN WINDOW FUNCTION:
- Press the "AUTO" button (IV) to start this func-
tion. The open window indicator (7) will turn on.
- In this function the appliance will check and re-
cord the room temperature constantly. When it
detectes that the temperature has dropped 3ºC
or more in 1 minute, the appliance will turn off.
This function works smartly to save energy.
- Press the "AUTO" button (IV) again to cancel
this function.
DELAY FUNCTION:
- This appliance can be turned on and off after
set times, when it is on standby mode.
- Press the "DELAY" button (IX) once to set the
"turn-on" timer. The "delay" indicator (11) will
turn on and the LED display will show "I/W".
- Use the "+" (XI) or "-" (VI) buttons to select the
desired time until "turn on" (1-24h).
- Press the "DELAY" button (IX) again to set the
"turn-off" timer. The "delay" indicator (11) will
turn on and the LED display will show "II/H".
- Use the "+" (XI) or "-" (VI) buttons to select the
desired time until "turn off" (1-24h).
CHILD-LOCK FUNCTION:
- Press the "LOCK" button (VIII) once to activate
the child lock. All the indicators besides de
"ON" indicator (4) will turn off. Neither the
control remote nor the control panel will be
operative.
- To cancel this function, press the "LOCK"
button (VIII) again. The indicators will turn back
on and the remote control and control panel will
be operative again.
SWING FUNCTION:
- Press the "SWING" button (III) once to activate
the oscilation of the air outlet.
- To cancel this function, press the "SWING" but-
ton (III) again. The air outlet will stop oscillating.
ONCE YOU HAVE FINISHED USING THE
APPLIANCE:
- Turn the appliance off, by pressing the on/off
button.
- Unplug the appliance from the mains.
- Clean the appliance.
SAFETY THERMAL PROTECTOR:
- The appliance has a safety device, which pro-
tects the appliance from overheating.
- When the appliance switches itself on and
off repeatedly, for reasons other than the
thermostat control, check to ensure that there
are no obstacles that impede correct air entry
or expulsion.
- If the appliance turns itself off and does not
switch itself on again, disconnect it from the
mains supply, and wait for approximately 15