Herunterladen Inhalt Inhalt Diese Seite drucken

Pelgrim IDK664 Anleitung Seite 54

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

54
installation
2 lives with 1 neutral connection (2 1N a.c. 400 V / 50 Hz):
The voltage between the phases and the neutral is 230 V a.c. Between the lives
there is a voltage of 400 V. If there is not a voltage of 400 V between the
lives, two wires have been taken from the same live in the meter cupboard
and the hob must be connected with two neutral wires, as indicated
above under 2 lives with 2 neutrals. Install a connecting bridge between the
connection points 3-4. Your groups must be fused with at least 16 A (2x). The
connecting power cable must have a minimum core cross section of 2,5 mm
Special connections
1 phase connection (1 1N a.c. 230 V / 50 Hz):
The voltage between live and neutral is 230 V a.c.
Install connecting bridges between connection points 1-2 and 3-4.
Your group must be protected by a fuse of at least 32 A. The connecting power
cable must have a minimum core cross section of 6 mm
1N a.c. 230V / 50 Hz
4
3N a.c. 400 V / 50 Hz
generators left
generators
right
4
3
2
1
generators left
generators
right
3
2
1
appliance
internal
.
2
appliance
internal
.
2

Werbung