Wiring must comply with applicable electrical standards and
include a properly sized fuse or circuit breaker. Improper
wiring can cause a fire resulting in injury or death.
CAUTION
IF YOU ARE NOT FAMILIAR WITH APPLICABLE
ELECTRICAL STANDARDS, HAVE THE UNIT INSTALLED BY A
QUALIFIED ELECTRICIAN.
CAUTION
Suggested wiring information is given as a
reference. For proper information, please reference ABYC E-11,
AC and DC Electrical Systems on Boats guidelines.
Wire Size Table
Total Wire Length - feet (meters)
Pump
Voltage
12 VDC
24 VDC
CAUTION
Motor case could get hot during extended
operation. Prolonged contact with skin may cause a burn.
CAUTION
Install a strainer in an accessible location (for
inspection and cleaning) between the tank and pump inlet in
order to protect valves from debris.
Operation
• Fill water tank
• Open all faucets
• Turn pump switch "ON"
NOTE: Expect a 10 second delay for power up.
Figure 6.
• When water is free of air, turn all faucets off beginning with
the faucet closest to the pump (Figure 6)
Important: Do not operate the pump more than 15 minutes
continuously.
WARNING
FI RE HAZA R D
0 - 20 ft
(0 - 6 m)
#14 AWG
#12 AWG
(2.5 mm
)
2
#16 AWG
#14 AWG
(1.5 mm
)
(2.5 mm
2
Initial Start Up
Initial Start Up
Demand Off
Demand Off
Demand On
Demand On
20 - 35 ft
35 - 55 ft
(6 - 9 m)
(9 - 12 m)
#10 AWG
(4 mm
)
2
#12 AWG
)
2
(6 mm
)
2
(4 mm)