The distance between drawer A and the
hob should be at least 10 mm. No extra
modifications for ventilation need be made
where there is a fixed panel (see fig. 11).
min.
10 mm
min.
560 x 6 mm
150
A
Fig. 11: Drawer under hob
Attention
Ensure that the connection cables hang
freely. If there is a drawer underneath the
hob, make sure that the contents do not
project above the edge of the drawer and
interfere with the ventilation.
Installation of the induction hob above a combi-
microwave oven, microwave oven or oven
2
50 cm
e
t
e
r
Fig. 12
e
Saw out the ventilation opening(s), making sure
that the total surface of the holes is a minimum
of 100 cm
2
. See fig. 12, for example, showing
2 holes of 50 cm
2
.
r
Fit a protective plate between the oven and
the hob. The plate should be at least 10 mm
thick and heat-resistant (85 °C). The space
between the underside of the hob and the
protective plate must be at least 50 mm.
t
To protect the air flow, fit a protective panel - of
the same material as the protective plate -
between the protective plate and the hob.
Ventilation is via the adjoining cupboards.
t
e
r
Fig. 13
min.
560 x 6 mm
52
50
200
Fig. 14

Electrical connection

Refer to the figure below for the wiring
diagram, which can also be found on the
underside of the appliance.
1
L
1
2
3
N
1
4
5
1N a.c. 230V
L
1
1
L
2
2
3
N
1
4
5
2N a.c. 400V
Brown
Yellow
L
1
1
L
2
2
N
3
1
N
4
2
5
2 2N a.c. 230V
L
1
1
L
2
2
3
L
3
4
5
3 a.c. 230V
Black
Black
Blue
Green
and