Herunterladen Inhalt Inhalt Diese Seite drucken

Installation - Franke MARIS Installations- Und Gebrauchsanweisung

Gaskochfeld
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 14
EN
FHMA 604 3G DC / FHMA 755 4G DC/DCL / FHMA 905 4G DCL / FHSM 604 3G DC
MOD.
FHSM 604 4G
FHSM 604 3G DC
FHSM 755 4G DC
FHSM 905 4G DCL
FHMA 604 3G DC
FHMA 755 4G DC
FHMA 755 4G DCL
FHMA 905 4G DCL
DC = Double Crown SR-Semi-Rapid R = Rapid AUX=Auxiliary C = Cast Iron Grid E = Enameled Grid

INSTALLATION

Installation and electrical/gas
connection must only be carried out by
specialized and licensed personnel.
The manufacturer declines any liability for
injury to persons or damage to things due to
failure noncompliance with these provisions.
The gas connection must comply with the
regulations in force in the country at the time
of installation.
Z
Ensure that the device is connected
directly to the mains socket. Ensure that
no adapters, no multi-sockets and no
extension cables are used to connect
the device.
Cabinet requirements
This handbook refers to a class 3 built-in gas
hob and type Y for electric part.
The gas pipe must not come into contact with
the sides of any oven under the hob.
For fitted units, the components (plastic
materials and veneered wood) must be
assembled with heat-resistant adhesives (min.
100°C): Unsuitable materials and adhesives
can result in warping and detachment.
FHSM 604 4G / FHSM 755 4G DC / FHSM 905 4G DCL
MODELS'S CONFIGURATION
nr
nr
nr
nr
N
Heat
AUX
SR
R
DC
burners
Source
1
2
1
4
1
2
1
4
1
2
1
1
5
1
2
1
1
5
1
2
1
4
1
2
1
1
5
1
2
1
1
5
1
2
1
1
5
Power supply = 220-240 V; Frequency = 50-60 Hz; Power/current = 0,6 Watt
Total
Total
Rated
Rated
Capacity
Capacity
G20
G30/G31
(m
/h)
(g/h)
3
GAS
0,713
545
GAS
0,742
567
GAS
1,028
785
GAS
1,028
785
GAS
0,742
545
GAS
1,028
764
GAS
1,028
764
GAS
1,028
764
The Ventilation of rooms must be in compliance
with local regulation.
The kitchen element must allow sufficient room
for the electrical connections of the appliance.
Important: These devices are „Y" type with
respect to the degree of protection against
the dangers of fire. The minimum distance
from the edge appliance is 150 mm for the
side wall, 50 mm for the rear and 700 mm
for any cabinets above it. The appliance is
recommended to be built into 40 mm thick
worktops. In case the dimensions are different,
eventual modifications have to be managed by
the technician.
Note: if a hood is installed above the hob,
for the distance to be respected refer to the
assembly instructions of the hood.
– 6 –
Air
Tot.
Tot.
Neccessary
Installed
Installed
for
Gas
LPG
combustion
Rated
Rated
(m
/h)
Power
Power
3
(kW)
(kW)
15
7,5
7,5
15,6
7,8
7,8
21,6
10,8
10,8
21,6
10,8
10,8
15,6
7,8
7,5
21,6
10,8
10,5
21,6
10,8
10,5
21,6
10,8
10,5
Weight
(net - gross)
(kg)
8-9,4 (C)
l
7,1-8,5 (E)
8-9,4 (C)
7,1-8,5 (E)
10,5-12(C)
8,9- 10,4 (E)
14- 15,7 (C)
12,5-14,2(E)
8,8-10,2 (C)
11,5-13 (C)
11,5-13 (C)
14,5-16,2 (C)

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis