ENGLISH
When the security of the code is not crucial, the on-board receiver can be used to
add a transmitter via xed-code cloning: while opting not to use the rolling code,
this still gives us a code with a large number of combinations, at the same time
we still have the option of "copying" any previously programmed transmitter.
PROGRAMMING
Transmitters can be memorized in manual mode or by means of the UNIRADIO
programmer, which allows the installation's complete database to be managed
via the EEdbase software.
In the latter case, the receiver is programmed by connecting UNIRADIO to the
VENERE D control panel, using the UNIFLAT and UNIDA accessories.
9.3) MANUAL PROGRAMMING
In the case of standard installations in which advanced features are not required,
transmitters can be memorized manually, referring to Fig.B for the basic pro-
gramming.
-
If you want the transmitter to activate output 1 (START) with key 1 or key 2
or key 3 or key 4, enter the transmitter in the start key menu as illustrated in
Fig.B.
-
If you want the transmitter to activate output 2 (2nd radio channel relay) with
key 1 or key 2 or key 3 or key 4, enter the transmitter in the 2ch key menu as
illustrated in Fig.B.
Note: The hidden key P1 changes appearance depending on the transmitter
model. For transmitters featuring a hidden key, press the hidden button P1
(Fig.B1).
For transmitters with no hidden key, simultaneously pressing the transmitter's
4 keys, or opening the battery compartment and using a screwdriver to jump
the two P1 points (Fig.B2), is equivalent to pressing key P1.
IMPORTANT NOTE: THE FIRST TRANSMITTER MEMORIZED MUST BE IDENTI-
FIED BY ATTACHING THE KEY LABEL (MASTER).
In the event of manual programming, the rst transmitter assigns the RECEIVER'S
9.4) CLONING RADIO TRANSMITTERS
Cloning with rolling code/Cloning with xed code
Refer to the UNIRADIO instructions and CLONIX programming guide.
9.5) ADVANCED PROGRAMMING: RECEIVER COMMUNITY
Refer to the UNIRADIO instructions and CLONIX programming guide.
9.6) REMOTE TRANSMITTER PROGRAMMING (Fig.20)
1) Press the hidden key (P1) of a transmitter that has already been memorized
in standard mode via manual programming.
2) Press the normal key (T1-T2-T3-T4) of a transmitter that has already been
memorized in standard mode via manual programming.
3) The courtesy light ashes. Press within 10 sec. the hidden key (P1) of a trans-
mitter to be memorized.
4) The courtesy light remains steadily lit. Press the normal key (T1-T2-T3-T4) of
a transmitter to be memorized.
The receiver exits programming mode after 10 sec.: you can use this time to enter
other new transmitters.
This mode does not require access to the control panel.
10) SERIAL CONNECTION VIA SCS1 CARD (Fig.20A)
The VENERE D control panel's special serial inputs and outputs (SCS1) make the
centralized connection of a number of automated devices possible. That way,
all the automated devices connected can be opened or closed with a single
command.
Connect all VENERE D control panels using twisted pair cabling only, proceeding
as shown in the diagram in Fig.20A.
When using a telephone cable with more than one pair, it is essential to use wires
from the same pair.
The length of the telephone cable between one unit and the next must not
be greater than 250 m.
At this point, each VENERE D control panel needs to be con gured appropriately,
starting by entering a MASTER control panel that will have control over all the
others, which therefore have to be set as SLAVE units (see logic menu).
Also set the Zone number (see parameters menu) in the range 0 to 127.
The zone number allows you to create groups of automated devices, each of
which answers to the Zone Master. Each zone can have only one Master: the
Master of zone 0 also controls the Slaves of the other zones.
11) EMERGENCY MANOEUVRE
In case of electric power failure or system malfunction, the manoeuvre must be
carried out manually by pulling the wire connected to the carriage, as in g.21.
For garages which are not provided with a second exit, it is compulsory to t an
external key release device like Mod. SM1 ( g.22) or Mod. SET/S ( g.23).
12) AUTOMATION CHECK
Before the automation device nally becomes operational, scrupulously
check the following conditions:
etc) operate correctly.
by the current standards, and anyway not too strong for the installation and
operating conditions.
during the manoeuvre.
Check the opening and closing operations using the control devices tted.
18 -
BOTTICELLI VENERE D
Downloaded from
www.Manualslib.com
INSTALLATION MANUAL
manuals search engine
13) AUTOMATION DEVICE USE
Since the automation device can be remotely controlled by means of a radio control
device or a Start button, and therefore when not in sight, all the safety devices must
any malfunction, request immediate assistance from quali ed personnel. Children
must be kept at a safe distance from the automation operation area.
14) AUTOMATION CONTROL
The use of this control device allows the gate to be opened and closed automati-
access etc.) depending on the installation requirements and characteristics. For
the various control systems, see the relevant instructions. The automation device
users must be instructed on control and operation.
15) ACCESSORIES
SM1
External release device to be applied to the cremone bolt already tted
to the overhead door ( g.22).
SET/S External release device with retracting handle for sectional doors measur-
ing max 50mm ( g.23).
ST
Automatic bolt release device for spring-operated overhead doors.
Fitted to the control arm, it automatically releases the side door bolts
( g.24).
16) MAINTENANCE
Before carrying out any maintenance operation, disconnect the system power
supply.
clutch.
the system power supply and request the assistance of a quali ed technician
(installer). When the product is out of service, activate the manual release
device to allow the door to be opened and closed manually.
If the power supply cable is damaged, it must be replaced directly by our
company or our technical service department or by a technician having
similar quali cation so as to avoid any risks.
16.1) FUSE REPLACEMENT (Fig.25)
WARNING! Disconnect the mains voltage.
Remove the rubber protection from the fuse-carrier. Remove the fuse (Fig.25,
Ref.A) to be replaced and replace it with a new one. After completing this opera-
tion, re- t the rubber protection.
17) SCRAPPING
Warning! This operation should only be carried out by quali ed person-
nel.
Materials must be disposed of in conformity with the current regulations.
In case of scrapping, the automation devices do not entail any particular risks or
danger. In case of materials to be recycled, these should be sorted out by type
(electrical components, copper, aluminium, plastic etc.).
18) DISMANTLING
Warning! This operation should only be carried out by quali ed personnel.
When the automation system is disassembled to be reassembled on another
site, proceed as follows:
aged, they must be replaced.
The descriptions and illustrations contained in the present manual are not
binding. The Company reserves the right to make any alterations deemed
appropriate for the technical, manufacturing and commercial improvement
of the product, while leaving the essential product features unchanged, at
any time and without undertaking to update the present publication.
-