Herunterladen Inhalt Inhalt Diese Seite drucken

Statistics Screen; Audible Sounds - Desoutter ESP-CA Serie Betriebsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 46
11/03/09 09:43 PR1 P15 S 20% 320RPM 00/03
NOK TMAX Program 1
11/03/09 09:43 PR1 P15 S 20% 320RPM 01/03
OK_ ____ Program 1
11/03/09 09:43 PR1 P15 S 20% 320RPM 02/03
OK_ ____ Program 1
11/03/09 09:43 PR1 P15 S 20% 320RPM 03/03
OK_ END_ Program 1
Description:
-
Date (day/month/year),
-
Hour (hh:mm)
-
Program number (PR1),
-
Model (in this example P15 means SLC150)
-
Joint (S = soft – H = hard)
-
Torque,
-
Speed (RPM)
-
Done/total Screws
-
Result (OK-NOK)
-
Error description and END (TMIN if the error
is of the min time, TMAX if max time, END
when cycle is ended)
-
15 letters description.
To export and display these data in an Excel file:
● Capture these data in an Excel sheet.
● Then re-select them
● Select DATA, TEXT TO COLUMNS, FIXED
WIDTH
● Push twice CONTINUE
● Set the Done/Total Screws column as text.
● Now each single data has its own cell: this
allows to make any statistics.

5.5. STATISTICS screen

To progress to the fourth screen, push MENU
again.
1
STATISTICS
SCREW OK
SCREW NOK
0
2
T. SCREWS
T. CYCLE
0
NO
Legend
1
STATISTICS screen
Here you can see the statistics of each single
program.
5.5.1. SCREW OK
Total number of correct tightenings done
between MIN and MAX TIME.
Torque signal: ok.
05/2020
PR 1
CYCLE OK
CYCLE NOK
0
0
TOTAL
RESET
0
NO
5.5.2. SCREWS NOK
Total number of not OK tightening, which have
fallen outside the set time parameters.
5.5.3. CYCLE OK
Total number of correctly completed cycles in
each pre-set Program.
5.5.4. CYCLE NOK
Total number of cycles where the quantity of the
rejected screws is higher than the preset number
of rejected screws.
5.5.5. T. SCREWS
Total number of tightenings for each cycle.
5.5.6. T. CYCLES
Total number of cycles done.
5.5.7. TOTAL
Total number of tightenings done from the
installation of the program (no possible reset).
5.5.8. RESET
If you set YES, all the statistics of the program
you are in will reset.

5.6. AUDIBLE SOUNDS

Each time you push a button or you move
through the screens, the unit mutters a 0,5 sec
audible sound.
Torque reached under min time, during the slow
start time or during the final phase (only HARD
JOINT) will result in a SINGLE NOK signal (see
below) and three x 1 sec audible sound.
6159932380
Issue no: 05
13 / 296

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis