Configuration Examples
4 Channel Operation
Place the connections as shown in the diagram.
Filter Selection Full Range Amplifier
Place the switches of HP and LP filters (16;20,22) in OFF position.
Place the switches (9;13) in STEREO position.
SOURCE UNIT
12V
switched
Your amplifier will now operate in full range mode. The incoming signal is amplified, but the frequency range
remains unchanged.
Connection of a Control Device with only 2 Pre-Amplifier Exits
Select the corresponding signal entry with switch (14). Front or rear. All 4 channels are now in operation.
22
PA 1054
Left
Front
PA 1054
FUSE
Left
Right
Rear
Front
Right
Rear