Accessories
To ensure smooth operation of the pump, OASE recommends the connection of a filter on the intake side. The satellite
filter ID is particularly suitable for this purpose. 57177 and/or Aqua Skim ID. 56907 (if necessary, in conjunction with
the Y distributor (ID. 56630).
S
Malfunction
Malfunction
The unit does not perform its suction function
Water flow insufficient
Unit switches off after a short running period
Spare parts
The use of original parts from OASE ensures continued
safe and reliable operation of the unit.
Please visit our website for spare parts drawings and spare
parts.
Wear parts
• Impeller unit
Storage/overwintering
The unit is not frost-proof and has to be removed and put into storage if minus temperatures are expected.
How to correctly store the unit:
• Drain the unit as far as possible, clean thoroughly and check for damage.
• Empty all hoses, pipes and connections as far as possible.
• Thoroughly clean the unit, check it for damage and replace any damaged parts.
• Store the pump submerged and in a frost-free environment.
• Protect open plug connections from moisture and dirt.
Repair
A damaged unit cannot be repaired and must be put out of operation. Dispose of the unit in accordance with the regu-
lations.
Disposal
N O T E
Do not dispose of this unit with domestic waste.
• Render the unit unusable beforehand by cutting the cables and dispose of the unit via the return system
provided for this purpose.
10
Cause
No mains voltage
Impeller blocked/running dry
Water supply soiled
Hose blocked
Hose kinked
Excessive loss in the hose due to friction
Water supply blocked
Unit running dry
www.oase-livingwater.com/spareparts
Remedy
Check mains voltage
Clean/check supply lines
Clean
Clean, or replace, if necessary
Check hose, and replace, if necessary
Reduce hose length to reduce frictional loss
Clean
Check supply line