7.3.2

Index 0x0047: Resolution

The parameter Resolution defines the measuring system resolution.
Index
0x0047
Value
Assignment
0x00
10 mm
0x01
1 mm
0x02
1/10 mm
0x03
1/100 mm
0x04
1/10 Inch
0x05
1 Inch
0x06
1/8 mm
0x07
Free Resolution
7.3.3

Index 0x0048: Free Resolution

The parameter Free Resolution defines the measuring system resolution, if under parameter
Resolution the option Free resolution was selected. Input in 1/100 mm.
Index
0x0048
Lower limit
Upper limit
Default
7.3.4

Index 0x004A: Dynamic Position Range

Dynamic Position Range is a parameter, who characterizes mathematic calculation of the
measure-value. With high measuring-dynamic there is no mathematic calculation on the measure-
value, but the noise of the measure-value is larger, in case of small measuring-dynamic the noise is
lower, but there exist a small time-delay for the measure-value.
Index
0x004A
Value
Assignment
0x00
High
0x01
Medium
0x02
Low
0x03
No Moving Average
Printed in the Federal Republic of Germany
06/15/2020
Subindex
Name
0
Resolution
Description
1 Digit = 1 centimeter
1 Digit = 1 millimeter
1 Digit = 1/10 millimeter
1 Digit = 1/100 millimeter
1 Digit = 1/10 inch
1 Digit = 1 Inch
1 Digit = 1/8 millimeter
1 Digit = 1/100 millimeter
Subindex
Name
0
Free Resolution
1
65535
100 (1 mm)
Subindex
Name
Dynamic Position
0
Range
Description
High measuring dynamic
Average measuring dynamic
Low measuring dynamic
Output of the raw value
TR - ELE - BA - DGB - 0030 - 01
Length
Type
8 Bit
UIntegerT
Length
Type
16 Bit
UIntegerT
Length
Type
8 Bit
UIntegerT
 TR-Electronic GmbH 2020, All Rights Reserved
Access
rw
Default
X
Access
rw
Access
rw
Default
X