BRS-FP/BRS-FPi
7 Operation
8 Decommissioning
9 Maintenance and cleaning
BAL.0028 • 2017-03-10
Downloaded from
www.Manualslib.com
NOTICE
• As the BRS-FP/BRS-FPi torch cleaning station is integrated into a welding system, the operating
instructions of the welding components, such as welding torch and robot control system, must be
observed during operation.
1 Switch on the robot control system.
2 Start the welding process.
3 Stop the welding process.
NOTICE
• As the BRS-FP/BRS-FPi torch cleaning station is integrated into a welding system, the process for
putting it out of operation depends on the robot control system. Make sure that the shutdown
procedures for all components integrated in the welding system are strictly observed.
1 Switch off the robot control.
Scheduled maintenance and cleaning are prerequisites for a long service life and trouble-free operation.
DANGER
Risk of injury due to unexpected start-up
The following instructions must be adhered to throughout all maintenance, servicing, assembly,
disassembly and repair work:
• Switch off the power source.
• Close off the gas supply.
• Close the compressed air supply.
• Disconnect all electrical connections.
• Switch off the entire welding system.
DANGER
Electric shock
Dangerous voltage due to defective cables.
• Check all live cables and connections for proper installation and damage.
• Replace any damaged, deformed or worn parts.
NOTICE
• Maintenance and cleaning work may only be carried out by qualified personnel
(in Germany, see TRBS 1203).
• Always wear your personal protective equipment when performing maintenance and cleaning work.
manuals search engine
7 Operation
EN - 21