EDS 4000 for Intrinsically Safe Circuits
7.1 Evaluation table (Protection concept): Assignment of the protection types and
application areas
Model code -
characteristic
Protection class
Application
Electrical
connection
(see model code)
Status: 2018-03-20
Downloaded from
www.Manualslib.com
1
I M1 Ex ia I Ma
Group
I
Category M1
Mining
Type of protection:
intrinsically safe
(ia) with barrier
5, 6, 8, A, G
manuals search engine
Protection concept
2
II 1G Ex ia IIC
II
T4, T5, T6 Ga
II 1/2G Ex ia IIC
T4,T5,T6 Ga/Gb
Group
II
Group
Category 1G
Category 2G, 1/2G
Gases
Gases
Type of protection:
Type of protection:
intrinsically safe
intrinsically safe
(ia) with barrier
(ia) with barrier
Use in:
Use in:
Zone 0
Zone 1
Zone 2
Mount to:
Zone 0
5, 6, 8, G
HYDAC ELECTRONIC GMBH
Page 15 of 26
3
8
2G Ex ia IIC
II 1D Ex ia IIIC
T4,T5,T6 Gb
T100° C Da
II
Group
Category 1D
Dust
Type of protection:
intrinsically safe
(ia) with barrier
Use in:
Zone 20
Zone 21
Zone 22
Mount to:
Zone 20
5, 6, 8, A, G
5, 6, 8, G
Mat. No.: 669736
II