EDS 4000 for Intrinsically Safe Circuits
Other data
Reverse polarity protection of the
supply voltage, load short-circuit and
overvoltage protection
Residual ripple supply voltage
Weight
Note:
1)
with mounted mating connector in corresponding protection class
2)
see model code „Insulation voltage"
6.2 EDS 44xx
Input data
Measuring ranges
Overload pressures
Burst pressures
Measuring ranges
Overload pressures
Burst pressures
Mechanical connection
Torque rating, recommended
Parts in contact with media
Output data
Switching output
Accuracy to DIN 16086, terminal
based
Temperature compensation
Zero point
Temperature compensation
Span
Repeatability
Long term drift
Ambient conditions
Compensated temperature range
Operation / ambient temperature range
Storage temperature range
- mark
Vibration resistance to
DIN EN 60068-2-6 at 10 .. 500Hz
Shock resistance to
DIN EN 60068-2-27 (1 ms)
Protection class to DIN EN 60529
Protection class to ISO 20653
Status: 2018-03-20
Downloaded from
www.Manualslib.com
Available
≤ 5 %
approx. 150 g (with connector)
approx 200g (with ½-14NPT Conduit)
FS (Full Scale) = relative to the full measuring range
bar
bar
bar
psi
psi
psi
Transistor output: PNP
Switching current: during operation I
Switching cycles: > 100 million
Switch point / hysteresis:
1)
Switch on and switch-off delay:
1)
≤ ± 0,5 % FS typ.
≤ ± 1,0 % FS max.
≤ ± 0,02 % FS / ° C typ.
≤ ± 0,03 % FS / ° C max.
≤ ± 0,02 % FS / ° C typ.
≤ ± 0,03 % FS / ° C max
≤ ± 0.1 % FS at 25 ° C
≤ ± 0.3 % FS / year
-25 .. + 85 ° C
T6:
T5,T4,T100:
-40 .. +100 ° C
EN 61000-6-1/ -2/ -3/ -4
EN 60079-0/-11/ 26
EN 61241-11
EN 50303
≤ 20 g
≤ 100 g
2)
IP 67 (connector M12x1, connector EN 175301-803)
IP 6K9K (1/2-14 NPT Conduit)
manuals search engine
EDS 4400 (relative pressure)
60
100
250
400
120
200
500
800
300
500
1000
2000
1000
3000
6000
9000
2900
7250
11600
14500
7250
14500
29000
29000
see model code / dimensions
see dimensions
Stainless steel:
1.4542, 1.4548, 1.4301, 1.4435, 1.4571, 1.4404
Seal:
FPM
depending on the version: factory set or
user-programmable with HYDAC HPG 3000/ ZBE P1
8 ms to 2000 ms; (Standard 32 ms)
depending on the version: factory set or
user-programmable with HYDAC HPG 3000/ ZBE P1
Ta = -20 .. + 60 ° C
Ta = -25 .. + 70 ° C
HYDAC ELECTRONIC GMBH
Page 12 of 26
600
1000
1600
2000
1000
1600
2400
3000
2000
3000
3000
4000
15000
20000
30000
23200
38400
43500
43500
43500
58000
≤ 34 mA
max
Mat. No.: 669736