When the oven is operating with the "Core
probe" or "Delta" function, the data with which it
is operating must be stored in order to comply
with current legislation with respect to HACCP.
The oven saves all the data for the operating
mode, Humidity, TC and TN (the lowest value
between TN1 and TN5) every minute while you
remain in the function in question. The data
must be stored for one month.
These data can be displayed on the screen or
downloaded to an external device using a de
USB or Ethernet.
Usage:
1. Connect the PC to the oven when it is
switched off.
2. Switch on the oven.
3. Confirm the option "START HACCP".
4. After
the
message
DOWNLOAD" switch off the oven.
VISUAL PLUS INSTRUCTIONS MANUAL
"END
HACCP

DESCALING

This function is used to access the descaling
cycle.
1) Press the descaling button.
2) Select time.
3) Warning "SPRAY DESCALER" (3 minutes).
4) Insert descaler in steam generator (rear
section of the oven).
5) Confirm.
6) On completion the following message is
displayed
"END DESCALING"
To descale, apply the chemical product in
the
quantities
manufacturer.
The volume of each generator is:
061
101
201
102
202
We recommend using a phosphoric acid
based product with a concentration of 30-
40%.
In this concentration, we recommend using
25% of the generator volume. In all cases,
please
observe
recommendations.
62
indicated
by
VE-VPE
VG-VPG
3
litre
----------------
5.5 litre
12.3 litre
5.5 litre
12.3 litre
5.5 litre
12.7 litre
11.1 litre
22.5 litre
manufacturer's