Stopping the data logger measurement program

DATA
Switch on testo 580 by pressing the DATA button.
Press STOP to end logging in the current measurement pro-
gram.
Successful data transfer is indicated by OK .
Note:
The STOP command is not carried out if
- DATA ERROR is shown.
- the function is blocked in the data logger.
The function can be released or blocked with the data logger
driver software.

Data logger: reprogramming and deleting the memory

Switch on testo 580 by pressing the DATA button.
DATA
If RESET is activated, the measurement program last used is set
up once again and the memory is deleted. Press Go to reboot
the data logger.
If the measuring program last used was set up with Start by
Date/Time , the data logger takes on the original time and rate
and sets the starting condition at Key start.
Note:
The old measurement protocol in the data logger is deleted.
Read out data logger beforehand.
OK appears if the data logger has been successfully programm-
ed.
Memory occupied in the data logger is at 0% following Reset.