Herunterladen Inhalt Inhalt Diese Seite drucken

BFT LEO B CBB 3 400 W01 Montageanleitung Seite 18

Selbstüberwachende steuerung
Vorschau ausblenden Andere Handbücher für LEO B CBB 3 400 W01:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 25
Logic
Definition
Configuration of
EXPI1 input on
input-output expan-
EXPI1
sion board.
Configuration of
EXPI2 input
on input-output
EXPI2
expansion board.
Configuration of
EXPO2 output
on input-output
EXPO1
expansion board
Configuration of
EXPO2 output
on input-output
EXPO2
expansion board
18 -
LEO B CBB 3 400 W 01
INSTALLATION MANUAL
Cross
out
Default
setting
used
0
1
2
3
4
5
6
7
8
9
10
1
1-2
11
12
13
14
0
1
2
3
4
0
5
6
1-3
7
8
9
10
1
2
3
1
4
4-5
5
6
7
9
8
9
6-7
10
Input configured as Start E command.
Input configured as Start I command.
Input configured as Open command.
Input configured as Close command.
Input configured as Ped command.
Input configured as Timer command.
Input configured as Timer Pedestrian command.
Input configured as Phot (photocell) safety.
Input configured as Phot op safety (photocell active during opening only).
Input configured as Phot cl safety (photocell active during closing only).
Input configured as Bar safety (safety edge).
Input configured as Phot test safety (tested photocell).
Input 3 (EXPI2) on input/output expansion board is switched automatically to safety device test
input, EXPFAULT1.
Input configured as Phot op test safety (tested photocell active during opening only).
Input 3 (EXPI2) on input/output expansion board is switched automatically to safety device test
input, EXPFAULT1.
Input configured as Phot cl test safety (tested photocell active during closing only).
Input 3 (EXPI2) on input/output expansion board is switched automatically to
safety device test input, EXPFAULT1.
Input configured as Bar safety (tested safety edge).
Input 3 (EXPI2) on input/output expansion board is switched automatically to
safety device test input, EXPFAULT1.
Input configured as Start E command.
Input configured as Start I command.
Input configured as Open command.
Input configured as Close command.
Input configured as Ped command.
Input configured as Timer command.
Input configured as Timer Pedestrian command.
Input configured as Phot (photocell) safety.
Input configured as Phot op safety (photocell active during opening only).
Input configured as Phot cl safety (photocell active during closing only).
Input configured as Bar safety (safety edge).
Output configured as SCA (gate open light).
Output configured as Courtesy Light command.
Output configured as Zone Light command.
Output configured as Stair Light.
Output configured as Alarm.
Output configured as Flashing light.
Output configured as Latch.
Output configured as Magnetic lock.
Output configured as Maintenance.
Output configured as Flashing Light and Maintenance.
Optional extras

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis