en
Operating temperature
Storage temperature
Max. rel. air humidity
Cable inlet
Sealing range of the
feed-through grommet
Housing material
Lens material
Installation position
Lens colors
4.2
Electrical data AC
Rated voltage
(See approvals for limit values)
Voltage range
Sounder current consump-
tion (max)
Flashing light current con-
sumption (max)
Power consumption
4.3
Electrical data DC
Rated voltage
(See approvals for limit
values)
Voltage range
Sounder current consump-
tion (max)
Flashing light current con-
sumption (max)
Power consumption
05/2020
4x M20 pre-embossed
7 – 13 mm
A cable gland with a sufficient degree of protection must be pro-
vided when cable diameters of < 7 mm are used.
PA 1
24 V
48 V
50/60 Hz
50/60 Hz
18 – 30 V 44 – 52 V 95 – 127 V 195 –253 V 18 – 30V 95 – 127V 195 – 253V
150 mA
110 mA
-
-
4.5 VA
4.5 VA
PA 1
24 V or
12 – 48 V
10 – 57 V
80 mA
-
12 – 48 V: 4 W
24 V: 2 W
Operating instructions PA 1 / PA X 1-05
-40 °C...+55 °C
-40 °C...+70 °C
90%
PC/ ABS Blend
PC
any
transparent, white, yellow, amber, red,
115 V
230 V
50/60 Hz
50/60 Hz
30 mA
16 mA
-
-
4.5 VA
4.5 VA
12 V
10 – 15 V
25 mA
700 mA
8 W
Page 3 / 11
5x M20 pre-embossed
green, blue
PA X 1-05
24 V
115 V
50/60 Hz
50/60 Hz
150 mA
30 mA
800 mA
120 mA
34.5 VA
18.5 VA
PA X 1-05
24 V
18 – 30 V
70 mA
360 mA
11.5 W
230 V
50/60 Hz
16 mA
90 mA
25 VA
48 V
40 – 57 V
80 mA
170 mA
11.5 W
086200000a