earthing rod and do not operate it while it is lying on the ground. Set the
device up in a non fire-hazard location.
COMMISSIONING:
Switch the device on with the push-button switch (PG.38/
seconds an LED lights up in the same rhythm as the impulses. The device
transmits impulses to the fence. If the LED does not light up, either the 9 volt
battery or the 12 volt rechargeable battery is spent. It could also be a defect
in the device or at the 230 volt mains adapter.
FARMER ABN30:
The incorporated current saving circuit is self-regulating and consumes less
energy with a well insulated fence.
COMMISSIONING WITH OPTIONAL 9 VOLT DRY BATTERY
(PG. 35/FIG.3,4 & PG. 36/FIG.6):
(use only alkaline batteries)
Open the housing and insert the 9 volt battery. Then connect the device to
the 9 V battery (red + / black -), ensure correct polarity.
flashing light
grenn
flashing light
red/green
5-15
%
flashing light
red
5
%
COMMISSIONING WITH OPTIONAL 12 V RECHARGEABLE BATTERY
(PG.35/FIG.3,4 & PG.36/FIG.6):
Place the batteries charged to 34 Ah in the lower section 87100 (12 Ah with
intermediate plate 87102). Place larger rechargeable batteries next to the
device (see PG. 34/FIG.2b). Then connect the device to the 12 V recharge-
able battery (red + / black -), ensure correct polarity and make sure the pole
terminals are clean. The connecting cable is included with the super fleece
rechargeable battery! Use the optional connecting cable (905010) for the 12
V special rechargeable battery. After a few seconds you will hear a steady
ticking indicating the device is in operation. The device will not start if the
polarity is reversed.
Only use rechargeable 12 V lead batteries; rechargeable batteries
with ventilation should only be recharged in well-ventilated rooms.
When charging with a charger that is not listed in these instructions
and is connected directly to the 12 V lead battery, you must remove
6
) - after a few
1
residual capacity
Battery good
15-100%
Replace battery
Battery fully depleted: Replace
the 9 V battery immediately
the rechargeable battery from the device. The rechargeable battery
should be stored and charged at normal room temperature before
and after every use as well as during longer periods of storage in the
house (every 2 months).
The rechargeable battery must be recharged by the latest when it has di-
scharged 80 % (only 20 % charge capacity left) to prevent complete dischar-
ge. The rechargeable battery indicator (PG.34/FIG.2a /
flashing light
green
flashing light
red/green
20-40%
flashing light
red
0-20%
Please note that the values can fluctuate depending on the temperature
(capacity ) and measurement deviations (voltage). For solar module opera-
tion, check the rechargeable battery indicator only at dawn (without sun-
light).
You can operate the device with the recommended optionally available
mains adapter, or charge the rechargeable battery with the optional solar
module in the sun or alternatively with the 230 V mains adapter. End the
charging process as soon as the green light of the battery indicator lights
up.
Avoid overcharging the rechargeable battery!
COMMISSIONING 230 V WITH OPERATIONAL MAINS ADAPTER
(PG.35/FIG. 7 & PG.36/FIG.5):
To operate on the 230 V mains, use only the mains adapter 47PSU-
0010FEU/FUK as specified on the intermediate plate in the device! After a
few seconds you will hear a steady ticking indicating the device is in operati-
on. The fence voltage indicator (PG.34/FIG.2a/
rhythm as the electrical impulses. With the mains adapter it is easy to charge
a connected 12 V rechargeable battery in parallel operation. If the 230 V
supply fails, the device is supplied from the rechargeable battery.
Disconnect the 9 V dry battery when operating with the mains adapter. Solar
operation is not possible when operating with a mains adapter.
COMMISSIONING WITH OPTIONAL SOLAR PANEL (≤ 20 W)
(PG. 37/FIG.7 & PG. 38/FIG.8):
The device has an incorporated solar charge regulator (when the device
farmer ABN30 & hotshock ABN37
) glows:
1
residual capacity
40-100%
Rechargeable battery good
Charge battery
Rechargeable battery fully
depleted: Recharge
immediately
) lights up in the same
1