FCONNECTIONS
Inlet,
Outlet,
optional
Connections could become leaky, if they are contaminated or corrupted
Therefore, the connections must regularly be checked for leak-tightness. Swap the product
where appropriate.
Keep all connections free from contamination, even small amounts of dirt can cause
connections to leak.
ASSEMBLY
Before assembly, check that the product is complete and has not suffered any damage during
transport.
ASSEMBLY must be carried out by a specialised company.
See USER QUALIFICATION!
The specialised company and the operator must observe, comply with and understand all of
the following instructions in this assembly and operating manual. For the system to function
as intended, it must be installed professionally in compliance with the technical rules
applicable to the planning, construction and operation of the entire system.
Consider installation location (see instructions on INTENDED USE).
Metal chips may cause eye injuries.
Wear safety goggles!
Malfunctions caused by residues! Proper functioning is not guaranteed.
Visually check that there are no metal chips or other residues in the connections!
It is important that metal chips or other residues are blown out!
Install with suitable tools, if required.
Regarding screw connections, use a second spanner to brace against the connection nozzle.
Do not use unsuitable tools, such as pliers.
Product damaged through incorrect installation direction
Proper functioning is not guaranteed.
Observe the installation direction (marked on the product with an arrow
6 / 12
Trading name and dimensions
acc. to standard
Combination soft (Komb.W)
• with gasket and 5-wing coupling nut
• G.19 = thread W 21.8 x 1/14 lh nut
Trading name and dimensions
acc. to standard
Ball-cone connector
• H.4 = Thread G 1/4-LH-KN
• H.6 = Thread G 3/8 lh M
Risk of injuries due to blown-out metal chips!
Caramatic BasicTwo
Installation notes
Tighten by hand!
Installation notes
Torques: G 1/4 = 5-7 Nm
Torques: G 3/8 = 15 Nm
).
part no. 02 018 51d