CLIP: the balancing adhesive weight must be
applied using the weight holder in ALU1P and
ALU2P programmes, whereas the spring weight
must always be applied in the 12 o'clock position.
- Use the Kis knob or the arrow buttons to select the
desired position. The selected icon is enabled
if it is in the following configuration:
- Press the Exit button to save the setting and
exit
.
The selected configuration is displayed on the
status bar in the working environment.
Unbalance rounding-off
configuration
Sets the unbalance rounding-off to grams x1 or
grams x5, or, if set to ounces, to oz x 1/4 or oz x 1/10,
with which the unbalance values are displayed.
Select the unbalance rounding-off
-
icon.
-
The following icons are displayed:
Set grams x1; displays the unbalance values
gram by gram.
Set grams x 5; displays the unbalance values
5 grams by 5 grams.
If the unit of measurement is ounces:
Set tenths of an ounce; displays the unbalance
values in tenths of an ounce.
Set fourths of an ounce; displays the unbalance
values in quarters of an ounce.
Press the the Kis knob or ENTER button to
-
select the icon desired.
-
Press the Exit button to save the setting and
exit
.
EM 9580 Plus - EM 9580 C Plus - Operator's manual
Unbalance unit-of measurement
(g/oz) configuration
Sets the unit of measurement to grams or ounces.
After the list of the setting programmes is dis-
played, proceed as follows:
-
Select the unbalance unit of measurement
icon
.
-
The following icons are displayed:
g; displays the unbalance values in grams.
oz; displays the unbalance values in ounces.
-
Press the
the Kis knob or
select the icon desired.
-
Press the Exit button to save the setting and
exit
.
After selecting, the new setting is saved and the
unbalance image is displayed again.
OPT warning configuration
Enables/disables the Optimisation programme
warning at the end of the spin. After the list of
the setting programmes is displayed, proceed
as follows:
- Select the Enable/Disable OPT warning icon
.
The following icons are displayed:
OPT OFF; deactivates the OPT warning.
OPT ON; activates the OPT warning;
- Press the Kis knob or the ENTER key to select
the required icon.
- Press the Exit button to save the setting and
exit.
The selection can also be seen in the working
screen status line.
ENTER button to
UK