Herunterladen Inhalt Inhalt Diese Seite drucken

Cardin Elettronica BL Serie Bedienungsanleitung Seite 19

24vdc motors 200
Vorschau ausblenden Andere Handbücher für BL Serie:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 33
Terminal board connections
7
CMN common for all inputs and outputs.
ELS electric lock output (fed continuously) 12 Vdc - 15 W.
8
9-10 LC-CH2 Potential free contact for the activation of the courtesy light (separate
power supply Vmax=30 Vac/dc: Imax=1A) or the second radio channel.
Selection is carried out using jumper "J5".
11
CMN common for all inputs and outputs.
12
LP 24 Vdc 25 W output for warning lights
intermittent activation (50%), 12,5 W continuous activation.
13
LS 24 Vdc 3 W output for an indicator light.
14
CMN common for all inputs and outputs.
15
30 Vdc controlled output, powering external loads
16
CMN common for all inputs and outputs.
30 Vdc output, powering external loads
17
18
TA (NO contact) opening button input.
19
TC (NO contact) closing button input.
TAL (NO contact) limited opening button input.
20
21
TD (NO contact) dynamic button input.
22
CMN common for all inputs and outputs.
TB (NC contact) stop button input (The opening of this contact interrupts the
23
All rights reserved. Unauthorised copying or use of the information contained in this document is punishable by law
cycle until a new movement command is given).
24
CSP (NC contact) safety edge input. Opening this contact will provoke a travel
direction inversion during the closing stage and during the opening stage
25
FTCS (NC contact) The opening of this contact will block all movement, until
the obstruction has been removed and the pause time has elapsed, due to
the safety device cutting in, the door will then continue moving in the closing
direction (only with automatic reclosing enabled).
26
FTCI (NC contact) safety and control devices in input (photocells invert the
travel direction when an obstruction is detected). Opening this contact will
provoke a travel direction inversion during closure due to the cutting in of the
safety device.
EMRG2 (NO) emergency manoeuvre input 2.
27
28
EMRG1 (NO) emergency manoeuvre input 1.
29
CMN common for the emergency buttons.
30
Inner conductor for radio receiver antenna (if an external antenna is fitted use
a coaxial type cable RG58 with an impedance of 50Ω).
31
Outer conductor for radio receiver antenna.
10
J1
F3
L3
J2
10
Collegamento motori/encoder a 4 fili
Connecting motor/4-wire encoder
Branchement moteur/encodeur à 4 fils
Anschluss der Motor/Encoder mit 4 Drähten
Conexionado motores/encoder de 4 conductores
COLORE
CABLAGGI
Bl
Blu
Gr
Verde
Gy
Grigio
Yw
Giallo
KABELFARBEN
Bl
Blau
Gr
Grün
Gy
Grau
Yw
Gelb
ENCODER 1
M1
Bl
Gr
1
2
3
4
B1
Signal buzzer "via radio" mode
CSER Serial connection (only for diagnostics)
D1
Six-segment LED display
DS1
Selection dip-switch
F1
10A blade fuse
(motor power protection)
(6)
F2
10A blade fuse
(motor protection during battery operation)
(6)
F3
4A
blade fuse
(24V circuit protection)
(6)
F4
4A
blade fuse
(24V circuit protection during battery operation)
(6)
F5
4A
blade fuse
(6)
(electric lock protection)
J1
Battery connection
Drawing number :
DC0406
CC24??????????
Product Code :
.
(1)
.
(1)
4A
F2
F4
L2
L1
F1
COLOUR CODE COLORATION
CODE
DES CÂBLAGES
Blue
Bleu
Green
Vert
Grey
Gris
Yellow
Jaune
COLORACIÓN
CABLEADOS
Azul
Verde
Gris
F5
Amarillo
ENCODER 2
M2
Gy
Yw
Bl
Gr
Gy
Yw
5
6
1
2
3
4
5
6
Description :
CENTRALINA 2 MOTORI CC CON ENCODER
Note
The total of the 2 external device outputs must not exceed 10 W.
(1)
Note
Jumper "J6" identifies the type of safety edge connected to binding post 24:
(2)
- in position 1 the safety edge with NC contact is selected;
- in position 2 the safety edge with 8.2 kΩ contact is selected;
If you bridge the CSP input, move jumper "J6" to position 1 (NC).
ALL UNUSED NC CONTACTS MUST BE JUMPED and consequently the security
device test must also be deactivated (FTCI , FTCS - Dip 7 and Dip 8 "OFF").
If you want to activate the FTCI, FTCS test both the transmission and receiver parts
of the security devices must be connected to the binding post marked "CTRL 30
Vdc". If the test is active there will be a 1 second delay between the command
transmission and movement of the gate/s.
Switch on the power and make sure that the indicator LEDs are in the following
condition.
-
L1
Power on
-
L2
Battery charging
-
L3
Wrong battery connection
-
L4
Transmitter code programming indicator
-
L5
Indicator for the blocking button "TB"
-
L6
Indicator for the inverting photoelectric cells "FTCI"
-
L7
Indicator for the stop photoelectric cells "FTCS"
-
L8
Indicator for the safety edge "CSP"
(2)
.
-
L9
Indicator for the opening button "TA"
-
L10 Indicator for the opening button "TC"
-
L11 Indicator for the limited opening button "TAL"
-
L12 Indicator for the sequential command "TD/CH1"
Note
This LED is "ON" when the battery is charging.
(3)
Note
If this LED is "ON" invert the battery power cables immediately.
(4)
Note
Check that the activation of the safety devices switches the corresponding
(5)
LEDs off.
If the green power on LED "L1" doesn't light up check the condition of the fuses
and the power cable connection at the transformer primary.
If one or more of the safety LEDs do not light up check the contacts of the
relative security devices and check that the unused safety device contacts have
been bridged.
J3
L5
L6
J4
L7
J5
DS1
TD
RA
PLP
1 2
P2
3
LP
Pos.1 Pos.2
LS
FTCI
L4
TFTI
TFTS
SAP
P3
ELS
LC/CH2
7
8
9
10
11
12
13
14
15
J2
Transformer secondary protection
J3
Enable transmitter memorisation via radio
J4
Radio channel selection
J5
Binding posts 9, 10 selection (courtesy light/CH2 via radio)
J6
Safety edge selection CSP NC/8.2 kΩ
MM
Transmitter code memory module
P1
Programming button (PROG)
P2
Transmitter code memorization button (MEMO)
P3
Transmitter code cancellation button (DEL)
R1
Radio frequency module, 433 MHz for S449 transmitters
Note
: These are automotive type blade fuses (max. voltage 58 V)
(6)
Collegamenti scheda base
19
R1
B1
MM
L8
L9
L11
D1
L10
L12
CSER
1 2
3
J6
1 2
1 2
3
3
Pos.1 Pos.2
21
24
16
17
18
19
20
22
23
ON
OFF
(3)
OFF
(4)
OFF
ON
(5)
ON
(5)
ON
(5)
ON
(5)
OFF
OFF
OFF
OFF
CS 1283
DC 0406
P1
CMN
EMRG 1
EMRG 2
25
26

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Bl1924asw

Inhaltsverzeichnis