Indication lights on control panel

Indication light
see FLO
>
>
Low fuel level
>
Low Nilfi sk-ALTO AntiStone
(Anti-Scale) level
>
Service interval: Service due
in 20 hours
>
Service interval expired
>
Pump oil low

Other Faults

Fault
>
Power cord not properly
connected to power supply
>
High pressure nozzle worn
out
>
Pressure regulation set to low
pressure
>
Pump has drawn in air due to
detergent tank being empty
>
Detergent tank empty
>
Dirt in detergent tank
>
Suction valve at cleaning
agent inlet soiled
>
fuel contamination
>
Burner sooted or adjustment
incorrect
manuals search engine
Cause
see FLO
Fill fuel tank
Cold water operation possible
Fill Nilfi sk-ALTO AntiStone (Anti-
Scale) tank
Contact Nilfi sk-ALTO Service
Contact Nilfi sk-ALTO Service
Fill to proper level
Cause
Check power cord connetction
Check fuse (see chapter 9.4 Technical
Data)
Replace nozzle
Turn the twist grip on safety control
block clockwise (+)
Close detergent valve. Remove lance
from gun. Operate spray gun and let
machine run until air in pump is gone
and the machine is running normally/
calm again.
Fill detergent tank
Clean detergent tank
Remove suction valve and clean or
replace
Contact Nilfi sk-ALTO Service