Herunterladen Inhalt Inhalt Diese Seite drucken

Installation Notes - Dynacord PRO MATRIX SYSTEM DPA 4245 Bedienungsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Installation Notes

Generally, it is important to install the power amplifier in a way, that ensures unhindered front-to-rear
air circulation.
When installing the power amplifier in a closed rack-shelf system, please make sure that adequate air-
flow is guaranteed. The space between the rear panel of the amplifier and the inner wall of the rack-
case has to be at least 60 mm x 330 mm. A free space of at least 100 mm above the rack-shelf system
is needed to provide sufficient air circulation. Since, during operation, the temperature inside the rack
system could easily rise up to 40° C, the maximum allowable ambient temperatures of the rest of the
incorporated modules and appliances within a specific rack-shelf system have to be taken into careful
consideration.
When mounting the power am-
plifier inside of a closed rack
system, it is recommended to
use special rack-rails or optio-
nally available rack-mount ears
NRS 90235 (112733) to prevent
bending of the appliance's front
panel.
Note
The amplifier has to be protected from:
- water drops or splashes
- direct sunlight
- high ambient temperatures and the direct radiation of heat sources
- high humidity and moisture - heavy dust
- massive vibrations
Moving the amplifier from a cold into a warm environment can result in the occurrence of condensation
on inner parts. Operating the appliance is only permissible after it has accommodated to the altered
temperature (approximately after one hour).Should any foreign solid parts or liquids inadvertently in-
trude the enclosure, immediately unplug the device from the power source and have it checked at a
DYNACORD service center, before further use.Cleaning the appliance should not be performed using
chemical solvents or sprays, as this might damage the finish and could even cause hazard fire.
Before The First Operation
Before switching the amplifier's power on, the included mains cord has to be connected to a 230V
- 50/60 Hz wall outlet. On the appliance itself, the cord has to be connected to the 3-pole mains
socket.To remotely start the amplifier, it is necessary to connect an external 24 V power source to
the terminal strip POWER REMOTE. Providing correct connection and with an external power supply
being present, the POWER ON indicator will light and the power amplifier is ready for operation.The
mains switch POWER on the rear of the appliance is meant for service and maintenance purposes
only. Through bridging the mains switching relay this option provides the possibility to operate the am-
plifier without an external 24 V power supply connected.
Caution
The DPA-Series power amplifiers employ power-on switching delays of approximately 2 seconds.
Downloaded from
www.Manualslib.com
For maintained trouble-free operation of the appliance, the maximum admissible
ambient temperature of +40°C is not to be exceeded.
The mains switch POWER on the rear of the appliance is only meant for
maintenance. Remotely switching off the device is not possible when the
POWER switch is engaged.
manuals search engine
18

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Pro matrix system dpa 4260

Inhaltsverzeichnis