Object Object name
Light output 2
43
external light level
Light output 2
44
night input
Light output 2
45
disable
Light output 2
46
disable status
Switch
47
HVAC
HVAC
48
stay-ON time
HVAC
49
switch-ON delay
HVAC
50
slave input
51
Disable HVAC
HVAC
52
disabling status
Logic gate 1
53
input 1
Logic gate 1
54
input 2
Logic gate 1
55
input 3
Logic gate 1
56
input 4
57
Logic gate 1 output
58
Logic gate 1 output
Logic gate 1
59
disable
Logic gate 1
60
disable status
Logic gate 2
61
input 1
Logic gate 2
62
input 2
Logic gate 2
63
input 3
Logic gate 2
64
input 4
Logic gate 2
65
output
Logic gate 2
66
output
Logic gate 2
67
disable
Logic gate 2
68
disable status
Constant-lighting control 1,
69
switch input
Constant-lighting control,
70
dimming level 1
Constant-lighting control
71
light-level setting
Constant-lighting control,
72
stay-ON time
Constant-lighting control
73
switch input 1
Constant-lighting control
74
dim input 1
Constant-lighting control
75
Teach
Constant-lighting control,
76
switch 2
Constant-lighting control,
77
dimming level 2
Constant-lighting control
78
switch input 2
Function
DPT
Flag
Lux
9,004
CWT
ON/OFF
1,001
CWT
ON/OFF
1,001
CWT
ON/OFF
1,001
CRT
ON/OFF
1,001
CRT
10 s ... 65535 s
7,005
CRWT
0 s ... 65535 s
7,005
CRWT
ON/OFF
1,001
CWT
ON/OFF
1,001
CWT
ON/OFF
1,001
CRT
ON/OFF
1,001
CWT
ON/OFF
1,001
CWT
ON/OFF
1,001
CWT
ON/OFF
1,001
CWT
ON/OFF
1,001
CRT
0...255
5,001
CRT
ON/OFF
1,001
CWT
ON/OFF
1,001
CRT
ON/OFF
1,001
CWT
ON/OFF
1,001
CWT
ON/OFF
1,001
CWT
ON/OFF
1,001
CWT
ON/OFF
1,001
CRT
0...255
5,001
CRT
ON/OFF
1,001
CWT
ON/OFF
1,001
CRT
ON/OFF
1,001
CRWT
0 % ... 100 %
5,001
CRT
2 - 1000 lux
9,004
CRWT
10 s...65535 s
7,005
CRWT
ON/OFF
1,001
CWT
Brighter/darker
3,007
CWT
ON/OFF
1,001
CWT
ON/OFF
1,001
CRWT
0 %...100 %
5,001
CRT
ON/OFF
1,001
CWT
KNX Application Description for 3000-Series
Object Object name
Constant-lighting control
79
dim input 2
Constant-lighting control
80
slave input
Constant-lighting control
81
external light level
Constant-lighting control
82
external light level
(DUAL light sensor only)
Constant-lighting control
83
night input
Disable constant-lighting
84
control
Constant-lighting control
85
disable status
9.1 Description of communication object status
Object
Description
Status
This object is always available.
This object feeds back whether the sensor selected in the Sen-
sor selected parameter in the general settings matches the sensor
fitted. It they do match, the relevant sensor type is returned; if the
combination does not match, a fault is returned and the sensor will
not work.
Product and associated hex value:
Fault 0x00
IS 3360 0x01
IS 3180 0x02
IS 345 0x03
HF 3360 0x04
IS 345 MX 0x05
Light sensor Dual 0x06
IS 3360 MX 0x07
9.2 Description of communication object
HF 3360 boost factor
Object
Description
Boost factor
This object is always available when the HF 3360 mo-
tion detector is selected.
This object is used for setting the boost factor for HF
3360 sensor reach.
9.3 Description of communication objects
light output X (1..2)
Object
Description
Switch light output X
This object is always available when the light output is
activated.
Light output X is switched with this object.
The group address linked with this object is used for
sending the switching command via bus to the actua-
tor, with it also being possible to request the switching
status from the detector.
Light output X
This object is only visible if the "Object light output"
dimming level
parameter is set to "Dimming level".
The group address linked with this object is used for
sending the dimming value via bus to the actuator, with
it also being possible to request this from the detector.
Light output X
This object is only visible if the "Object light output"
scene
parameter is set to "Scene".
The group address linked with this object is used for
sending the scene via bus to the actuator, with it also
being possible to request this from the detector.
Light output X
This object is always available when the light output is
switching threshold
activated.
The group address linked with this object is used for
receiving the switching threshold (in lux) for the light
output via bus; this threshold can be requested at any
time.
- 25 -
Function
DPT
Flag
Brighter/darker
3,007
CWT
ON/OFF
1,001
CWT
Lux
9,004
CWT
Lux
9,004
CWT
ON/OFF
1,001
CWT
ON/OFF
1,001
CWT
ON/OFF
1,001
CRT