Herunterladen Inhalt Inhalt Diese Seite drucken

External Signalling Device Connection; Relay Contact (N.o.); Operating Voltage Connection (12-16V/Dc) - Renkforce AC-239 Bedienungsanleitung

2-zonen alarmanlage
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

7.2 External Signalling Device Connection

A maximum of two 8 Ohm signalling
devices / speakers can be connected
in parallel to the terminal clamps 4 (-)
and 5 (+).

7.3 Relay Contact (N.O.)

The connection terminals 6 (+) and
(-) are a relay contact (N.O. – normal-
ly open). The relay contact can be set
for timing mode or latch mode. This
can be determined by jumper C (s.
chapter 9: Jumper function)
Timing Mode: The relay contact is
reset 3 minutes after an alarm was
triggered.
Latch mode: The relay contact remains activated after an alarm was triggered, until
the system is reset.
Optical or acoustic signalling devices can be connected.
Relay contact: 12V/DC, max. 5 ampere

7.4 Operating Voltage Connection (12-16V/DC)

The operating voltage (12-16V/DC)
is connected to the terminal clamps
7 (-) and 8 (+).
Activate the operational voltage only after completing all connections.
30
HORNS
1
2
3
4
5
STROBE LIGHT
OR OTHER
ALARM DEVICE
+
1
2
3
4
5
12VDC/500MA
MIN. POWER
ADAPTOR
+
1
2
3
4
5
8
8
6
7
8
9
10
12V DC
BELL
+
6
7
8
9
10
12V
OR
BATTERY
+
6
7
8
9
10
11
12
7
11
12
11
12

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis