11. cHANgINg THE DISpLAy vIEW

The upper part of the display can be used to show other values
instead of the indoor humidity and the indoor
temperature. The Display button is used to change the view.
RADIO ENERgy-SAvINg cONTROLLERS
In order to enable communication between radio components,
the devices have to be taught-in to one another. Proceed as
follows to allow radio energy-saving controllers to be managed
via a wall thermostat:
•   F irst of all, the radio energy-saving controller must be set 
to teach-in mode. For more information on this, refer to the
operating manual for the relevant device.
•   T he wall thermostat then needs to transmit a radio signal for 
teaching-in purposes. To do this, press and hold down the
OK button on the wall thermostat for longer than 3 seconds.
•   " LEA" and the remaining teach-in time (starting at 30 
seconds) appear on the display and the wall thermostat
transmits a teach-in signal.
•   W hen the radio energy-saving controller receives the teach-in 
signal, "ECF" appears on its display.
The wall thermostat can be taught-in to as many radio energy-
saving controllers as you wish.
If there is interference in terms of radio communication,
the radio energy-saving controller continues to regulate
the temperature autonomously, in accordance with the
most recent specifications made by the wall thermostat.
Remote controls or window contacts that have previously
been taught-in to the radio energy-saving controller must
be taught-in to the wall thermostat directly.