Herunterladen Inhalt Inhalt Diese Seite drucken

Kopp 840629041 Bedienungsanleitung Seite 27

Infracontrol r 180 up ip40
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
GB
Manual ON (button activation)
For this, connect one or more buttons to the normally open
contact on the T 5 terminal of the motion sensor.
Press the button (normally open contact) and switch the mo-
tion sensor ON (regardless of the set twilight threshold). The
motion detector switches off again in accordance with the set
duty cycle.
Technical data
Nominal voltage:
Permanent current:
Switching contact:
Frequency:
Standby power:
Detection angle:
Lens design:
Detection range: (at 20°C)
Recommended installation height:
Duty cycle (delay time):
Twilight threshold:
230 V~; +-5%
max. 10 A
normally open contact (μ opening width)
50 Hz
< 1 W
180°
3 levels
approx. 9 m with an installation height of approx. 1.2 - 1.5 m
approx. 8 m with an installation height of approx. 1.5 - 2 m
1,2 m to 2 m
5 levels: 20 sec / 1 min / 5 min / 15 min / 30 min
Test function: 2 sec.
Pulse (
): 1 sec ON / 9 sec OFF
5 to 1000 Lux
Save function ambient brightness
27

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis