Herunterladen Inhalt Inhalt Diese Seite drucken

General Safety Instructions; Inserting Battery - LaserLiner MetricStar Bedienungsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
Completely read through the operating instructions,
the "Warranty and Additional Information" booklet as
!
well as the latest information under the internet link at
the end of these instructions. Follow the instructions
they contain. This document must be kept in a safe
place and passed on together with the device.
Function / application
Digital calliper gauge for precise measurement of lengths
– Functions: External measurement, internal measurement,
depth measurement, differential measurement through
zero position, level measurement
– 5-digit display
– Measurement range: 0 ... 150 mm

General safety instructions

– The device must only be used in accordance with its intended
purpose and within the scope of the specifications.
– The device and its accessories are not toys.
– The structure of the device must not be modified in any way.
– Do not expose the device to mechanical stress,
extreme temperatures, moisture or significant vibration.
– When using the device outdoors, make sure that the
weather conditions are appropriate and/or that suitable
protection measures are taken.
– Risk of injury! Not suitable for measuring rotating workpieces.
– Risk of cuts! The measuring surfaces are sharp and pointed and
may cause injuries – only hold them using the handles provided.
Safety instructions
Dealing with electromagnetic radiation
– The measuring device complies with electromagnetic
compatibility regulations and limit values in accordance
with EMC-Directive 2014/30/EU.
– Local operating restrictions – for example, in hospitals,
aircraft, petrol stations or in the vicinity of people with pace-
makers – may apply. Electronic devices can potentially cause
hazards or interference or be subject to hazards or interference.
– The measuring accuracy may be affected when working close
to high voltages or high electromagnetic alternating fields.
Device description
1
Measuring jaws for
external measurement
2
On/Off switch
3
Zeroing the
digital display
4
Scale 0 ... 150 mm
1

Inserting battery

Open the battery compart-
ment and insert battery
(1x LR44 button cell)
according to the symbols.
Be sure to pay attention
to polarity.
06
EN
(see Figure A)
HOLD
ON/OFF
ZERO
5
Depth gauge
6
Measuring jaws for
internal measurement
7
LC display
8
Hold function
9
Battery compartment
1.
ON/OFF
2.
HOLD
ZERO

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis